Image 61

LYNXR/LYNXR24 PROGRAMMING DEFAULT TABLES

(boldface indicates defaults that differ between tables)

Function

Table 1

Table 2

Table 3

Table 4

*20

Installer code

4112

4112

4112

4112

*21

Quick arm enable

1

1

1

1

*22

Keypad backlight timeout

0

0

0

0

*23

Forced bypass

0

0

0

0

*24

RF house ID code

0,0

0,0

0,0

0,0

*25

Powerline carrier device house code

0

0

0

0

*26

Chime-by-zone

0

0

0

0

*27

Real-time clock display

1

1

1

1

*29

Daylight saving time start/end month

4,10

4,10

4,10

4,10

*30

Daylight saving time start/end weekend

1,5

1,5

1,5

1,5

*31

Single alarm sounding per zone

0

0

0

0

*32

Fire sounder timeout

0

0

0

0

*33

Alarm bell timeout

1

1

1

1

*34

Exit delay

7,0

6,0

7,0

7,0

*35 Entry delay 1 (zone type 01)

3,0

4,5

3,0

3,0

*36

Entry delay 2 (zone type 02)

6,0

6,0

6,0

6,0

*37 Audible exit warning/quick exit

1,1

0,1

1,1

1,1

*38

Confirmation of arming ding

0

0

0

0

*39

Power up in previous state

1

1

1

1

*40

PABX access code

---

---

---

---

*41

Primary phone number

---

---

---

---

*42

Secondary phone number

---

---

---

---

*43

Primary subscriber account number

15,15,15,15

15,15,15,15

15,15,15,15

15,15,15,15

*44

Secondary subscriber account number

---

---

---

---

*46

“Follow Me Reminder” Phone Number

---

---

---

---

*47

Phone system select

1

1

1

1

*48

Report format

7,7

7,7

7,7

7,7

*49

Split/dual reporting

0

0

0

9

*50 15 second dialer delay (burglary)

0

1

0

0

*51

Periodic test report

0

3

0

0

*52

First test report offset

2

2

2

2

*53

Sescoa/radionics select

0

0

0

0

*54

Lack of usage notification

0

0

0

0

*55

Wireless Dialer

0, 0, 0, 0

0, 0, 0, 0

0, 0, 0, 0

0, 0, 0, 0

*56

Enhanced Zone programming

See *56 table

See *56 table

See *56 table

See *56 table

*58

RF jam detection

0

0

0

0

*59 Exit error report code

1

0

1

1

*60

Trouble report code

1,0

1,0

1,0

1,0

*61

Bypass report code

0,0

0,0

0,0

0,0

*62

AC loss report code

0,0

0,0

0,0

0,0

*63

Low battery Report code

1,0

1,0

1,0

1,0

*64

Test report code

1,0

1,0

1,0

1,0

*65

Open report code

0

0

0

0

*66

Arm away/stay report code

0,0

0,0

0,0

0,0

*67

RF transmitter low battery report code

1,0

1,0

1,0

1,0

*68

Cancel report code

1,0

1,0

1,0

1,0

*70

Alarm restore codes

1

1

1

1

*71

Trouble restore report code

1,0

1,0

1,0

1,0

*72

Bypass restore report code

0,0

0,0

0,0

0,0

*73

AC restore report code

0,0

0,0

0,0

0,0

*74

Low battery restore report code

1,0

1,0

1,0

1,0

*75

RF transmitter low battery restore report code

1,0

1,0

1,0

1,0

*76 Test restore report code

0,0

1,0

0,0

0,0

*80

Powerline Carrier Devices

See *80 table

See *80 table

See *80 table

See *80 table

*81 Zone lists for devices

See *81 table

See *81 table

See *81 table

See *81 table

*84

Assign zone voice descriptors

 

Refer to *84

Programming

 

*87 Auxiliary Function/ 1-button paging

0

1

0

1

*88

Pager characters

---

---

---

---

*89

Event log 80% full report code

0,0

0,0

0,0

0,0

*90

Event logging

3

15

3

3

*91

LRR/AAV Trigger/Remote Phone Control

2

2

2

2

*92

Number of reports in armed period

0

0

0

0

*93

Flexible call back

0

0

0

0

*94

Download phone number

---

---

---

---

*95

Ring detect count for downloading/remote phone control

15

15

15

15

Default Master Code

1,2,3,4

1,2,3,4

1,2,3,4

1,2,3,4

Default Duress Code

---

---

---

---

By activating *96, Field 43, and 44 will be changed to 15, 15, 15, 15.

 

 

 

 