System Communication

This section provides an explanation of formats this system accommodates for reporting alarms and other system conditions to the central station. The process of a successful transmission consists of both the method of communication between the control panel and the central station receiver, and the actual way the information is sent and displayed at the central station.

Communication Overview

When the panel calls the central station receiver, it waits to hear a “handshake” frequency from the receiver to confirm that the receiver is on-line and ready to receive its message. Once the panel hears the handshake it is programmed to listen for, it sends its message. The panel then waits for a “kissoff” frequency from the receiver acknowledging that the message was received and understood.

3

If the handshake frequency is not given or is not understood by the panel, the panel will not send its message. Once the handshake frequency is received and understood by the panel, the panel will send its message. If there is an error in the transmission (the receiver does not receive a “valid” message), the kissoff frequency will not be given by the central station receiver.

The panel will make eight attempts to the primary telephone number and eight attempts to the secondary telephone number (if programmed) to get a valid message through. If the panel is not successful after its numerous attempts, the keypad will display “FC.” If the secondary number is a pager, “FC” displays after the first 8 attempts to the primary number.

The following chart defines the three sets of (handshake/kissoff) frequencies that the panel supports, and the different formats that can be sent for each.

FORMAT

HANDSHAKE

TRANSMITS DATA

KISSOFF

TRANSMIT TIME

Low Speed

1400Hz

1900Hz (10PPS)

1400Hz

Under 15 seconds

3+1

 

(Standard report)

 

 

4+1

 

 

 

 

4+2

 

 

 

 

Sescoa/Rad

2300Hz

1900Hz (20PPS)

2300Hz

Under 10 seconds

3+1

 

(Standard report)

 

 

4+1

 

 

 

 

4+2

 

 

 

 

Express

1400–2300Hz

DTMF (10 cps)

1400Hz

Under 3 seconds

4+2

 

 

 

 

Contact ID®

1400–2300Hz

DTMF (10 cps)

1400Hz

Under 3 seconds

Report Code Formats

3+1 and 4+1 Standard Formats

Comprise a 3- (or 4-) digit subscriber number and a single digit report

 

code (e.g. alarm, trouble, restore, open, close, etc).

 

 

3+1 and 4+1 Expanded Formats

Comprise a 3- (or 4-) digit subscriber number, and a 2-digit report

 

code. The first digit is displayed on the first line, followed by a second

 

line where the first digit is repeated 3 (or 4) times and followed by the

 

second digit. This is the “expanded” digit.

 

 

4+2 Format

Comprises a 4-digit subscriber number and 2-digit report code.

 

 

ADEMCO Contact ID®

Comprises a 4-digit subscriber number, 1-digit event qualifier

Reporting Format

(“new” or “restore”), 3-digit event code, and 3-digit zone number, user

 

number, or system status number (see the following page).

The following table shows the message formats for 3+1, 4+1 and 4+2 reports, where:

SSS or SSSS

=

Subscriber ID

 

C

= Close Code (1st Digit)

A

=

Alarm Code (1st digit)

U

=

User Number (in hex)

Z

=

Typically Zone Number* (2nd digit)

Gg

=

Test Code (1st & 2nd digits)

Tt

=

Trouble Code (1st & 2nd digits)

R

=

Alarm Restore Code

Bb

=

Bypass Code (1st & 2nd digits)

R T t

=

Trouble Restore Code (1st & 2nd digits)

EA C

=

AC Loss Code (1st & 2nd digits)

R B b

=

Bypass Restore Code (1st & 2nd digits)

LL B

=

Low Battery Code (1st & 2nd digits)

R A A C

=

AC Restore Code (1st & 2nd digits)

O

=

Open Code (1st Digit)

R L L B

=

Battery Restore Code (1st & 2nd digits)

*Zone numbers for: [*] & [#], or [B] = 99; [1] + [*], or [A] = 95; [3] + [#], or [C] = 96; Duress = 92

–54–

Page 54
Image 54
Honeywell LYNXR Series, LYNXR-EN setup guide System Communication, Communication Overview

LYNXR Series, LYNXR-EN specifications

The Honeywell LYNXR Series, particularly the LYNXR-EN model, represents a pinnacle of advanced security technology designed for residential and small business applications. This all-in-one wireless security system is lauded for its innovative features, ease of use, and powerful performance, making it a top choice among users seeking enhanced security solutions.

One of the standout features of the LYNXR-EN is its user-friendly touchscreen interface. The large, intuitive display allows for straightforward navigation, enabling users to arm or disarm the system, check status, and receive alerts with just a few taps. This ease of use is complemented by programmable quick access keys, which allow users to personalize their experience according to their security requirements.

Additionally, the LYNXR-EN is designed with flexibility in mind. It supports a wide range of wireless sensors and devices, facilitating comprehensive coverage for homes or small businesses. Users can integrate door and window contacts, motion detectors, glass break sensors, and more, ensuring that every entry point is monitored. The system can accommodate up to 48 wireless zones, allowing for extensive security applications without the clutter of wires.

Technologically, the LYNXR-EN leverages advanced RF technology, enhancing the reliability of communication between the panel and sensors. This feature minimizes the risk of interference and ensures consistent performance even in challenging environments. Along with this robust connectivity, the system offers dual-path communication capabilities, enabling both IP and cellular reporting. This redundancy ensures that alerts are promptly sent to the monitoring center and mobile devices, providing peace of mind to users.

Moreover, the LYNXR-EN can be easily integrated with smart home technology. It is compatible with various smart devices, allowing users to control lighting, thermostats, and other home automation features from a single platform. This integration not only enhances convenience but also optimizes energy efficiency.

The LYNXR-EN also includes a built-in battery backup, ensuring that the system remains operational during power outages. This is a crucial feature for maintaining security when it is needed most. Additionally, users can set up customizable alerts and notifications, allowing them to stay informed of any unusual activity in real-time.

In summary, the Honeywell LYNXR Series, especially the LYNXR-EN model, combines advanced technology with user-friendly design to deliver a versatile and robust security solution. Its wireless capabilities, comprehensive sensor support, smart home integration, and reliable communication make it a prominent choice in the ever-evolving realm of security systems.