AC Power and Backup Battery
The system is powered by a 9VAC, 15VA
Use only the provided ADEMCO 1332/1332X10 or 1332CN Transformer
Distance from Transformer | Wire Gauge |
to Control |
|
|
|
Up to 75 feet | #20 |
|
|
75 to 150 feet | #18 |
|
|
150 to 300 feet | #16 |
|
|
Wiring to the AC Transformer must not exceed 300 feet using
Do not plug the transformer into the AC outlet until after all wiring connections have been made.
Backup battery. In the event of an AC power loss, the system is supported by a long life backup battery that is supervised for connection and for low voltage conditions. If the battery is missing, or a low battery condition is detected, a “low battery” message is displayed and a report is sent to the central station. In addition, the system will beep once every 45 seconds to audibly indicate a low battery condition (press any key to stop the beeping).
AC Power and Rechargeable Backup Battery
Connecting AC Power and backup battery
1.Connect wires from the 1332/1332X10 (1332CN in Canada) AC Transformer to terminals 15 and 16 as shown in the wiring diagram.
2.Remove battery retainer.
3.Peel the backing from tape on the back plate.
4.Insert battery pack into back plate.
5.Install battery retainer.
6.Connect battery connector to receptacle on terminal block PC board.
7.After all wiring connections have been made, snap the front assembly to the back plate and plug the transformer into a
Note: Rechargeable batteries may take up to
RETAINER
BATTERY
PACK
TAPE
116
NOTE
BATTERY PACK SHOWN
M | XXXX | K5108 |
BATTERY | WIRING |
RECEPTACLE | TERMINALS |
Ensure the cover is snapped closed prior to applying AC power.