Mounting the Control
Wall Mounting
The illustration below shows the front assembly separated from the back plate.
DO NOT disconnect the ribbon cable from the terminal strip board. Disconnect the cable only from the
!front assembly board.
Certain features differ between the LYNXR/LYNXR24 and the
1.Separate the front assembly from the back plate by pressing on the two locking tabs at the top of the unit.
2. Carefully disconnect the ribbon cable from the front assembly, leaving the ribbon cable connected to the terminal block PC board. The back plate contains the terminal block for making wiring connections.
3.Mount the back plate to a sturdy wall, feeding the field wiring through the appropriate openings in the back plate.
4.After wiring connections are made, carefully reconnect the ribbon cable to the front assembly PC board connector (properly aligning the red wire).
5.Before closing the assembly, verify which LYNXR model is being installed by checking the model number printed on the PC Boards. (Example: SALYNXREN indicates the unit being installed is a
6.Snap the front assembly to the back plate so it is secured by the locking tabs.
PC BOARD
PART NUMBER
LOCATION
LOCKING TABS
16 | MXXXX | K5108 |
1
RED WIRE
MARKING
DISCONNECT
THIS END ONLY!
PC BOARD
PART NUMBER
LOCATION
Desktop Mounting
If desired, an optional mounting base (model
1.Slide the control panel onto the mounting base locking tabs.
2.Bring all wiring through the bottom of the mounting base, using one of the three wire entry locations, before making connections to the control panel.
3.Use
OFF
ESCAPE
AWAY
ADD
STAY
DELETE
AUX
SELECT
WIRE ENTRY KNOCKOUT (1 of 3)