Multiquip DCA-600SSK -TROUBLESHOOTING GENERATOR/ENGINE, Generator Troubleshooting, Symptom

Models: DCA-600SSK

1 116
Download 116 pages 26.58 Kb
Page 68
Image 68
DCA-600SSK —TROUBLESHOOTING (GENERATOR/ENGINE)

DCA-600SSK —TROUBLESHOOTING (GENERATOR/ENGINE)

Practically all breakdowns can be prevented by proper handling and maintenance inspections, but in the event of a breakdown, use Table 21 (Generator Troubleshooting) as a basic guideline for troubleshooting the generator. If the problem cannot be remedied, consult our company's business office or service plant.

TABLE 21. GENERATOR TROUBLESHOOTING

SYMPTOM

POSSIBLE PROBLEM

SOLUTION

 

 

 

 

AC Voltmeter defective?

Check output voltage using a voltmeter.

 

 

 

No Voltage Output

Is wiring connection loose?

Check wiring and repair.

 

 

Is AVR defective?

Replace if necessary.

 

 

 

 

 

Defective Rotating Rectifier?

Check and replace.

 

 

 

 

Is engine speed correct?

Turn engine throttle lever to "High".

 

 

 

Low Voltage Output

Is wiring connections loose?

Check wiring and repair.

 

 

 

 

Defective AVR?

Replace if necessary.

 

 

 

High Voltage Output

Is wiring connections loose?

Check wiring and repair.

 

 

Defective AVR?

Replace if necessary.

 

 

 

 

 

Short Circuit in load?

Check load and repair.

 

 

 

Circuit Breaker Tripped

Over current?

Confirm load requirements and reduce.

 

 

Defective circuit breaker?

Check and replace.

 

 

 

 

 

Over current Relay actuated?

Confirm load requirement and replace.

 

 

 

PAGE 68 — DCA-600SSK — OPERATION AND PARTS MANUAL (STD) — REV. #7 (04/30/10)