Multiquip DCA-600SSK - PRE-SETUP, Caution - Refuelingthe Generator, Full Trailer Tank

Models: DCA-600SSK

1 116
Download 116 pages 26.58 Kb
Page 42
Image 42
Figure 35. Full Trailer Tank

DCA-600SSKPRE-SETUP

3. NEVER overfill trailer fuel tank – It is important to 5. Figure 37 below reflects a full fuel system. read the trailer fuel gauge when filling trailer fuel tank.

DO NOT wait for fuel to rise in filler neck. SeeFigure35.

Figure 35. Full Trailer Tank

Figure 37. Full Fuel System

CAUTION - REFUELINGTHE GENERATOR

DO NOT OVER-FILLfuel system. Leave room for fuel expansion . Fuel expands when heated (Figure 36).

4.Once the trailer tank is full, the secondary inner tank can be filled (See Figure 36). Notice how the trailer filler tube level rises when the internal tank is filled.

Figure 36. Filling Secondary Internal Fuel Tank

6.Fuel from the engine return line will drain into the secondary internal fuel tank. This fuel will eventually drain into the primary trailer tank in order to return to the engine.

CAUTION - REFUELING SECONDARY FUELTANK

It is recommended to only fill the internal secondary take to 3/ 4 full in order to allow for fuel return, fuel expansion, and to avoid spillage. See Figure 38 for fuel expansion.

Figure 38. Fuel Expansion

PAGE 42 — DCA-600SSK — OPERATION AND PARTS MANUAL (STD) — REV. #7 (04/30/10)

Page 42
Image 42
Multiquip DCA-600SSK - PRE-SETUP, Caution - Refuelingthe Generator, Full Trailer Tank, Full Fuel System, Fuel Expansion