WARNING - BURN HAZARDS

Allow engine to cool when flushing out radiator. Flushing the radiator while hot could cause serious burns from water or steam.

Flushing Out Radiator and Changing Coolant

1.Stop the engine and allow to cool. Tighten valve of the corrosion resistor (if equipped).

2.Turn water filer cap slowly and remove it.

3.Prepare a container to catch the coolant, then open drain plug of the radiator or heat exchanger and drain plug of the engine, and drain the coolant.

4.After draining the coolant, close drain plugs and fill with tap water.

5.When the water level is near the mouth of the water filler, open drain plugs and start the engine, and run at low idling. Keep the engine running at low idling and flush the radiator for about 10 minutes.

6.Adjust the flow of the water flowing in and draining out to ensure that the radiator is always full during the flushing operation. While flushing water through the system, watch carefully the water inlet hose does not come out of the radiator filler port.

7.After flushing, stop the engine, open drain plug and drain the water, then close drain plugs.

8.After draining the water, flush the system with a flushing agent. See instructions on flushing agent label.

9.After flushing, open drain plugs and drain out all the water, then close drain plugs and add tap water so the water level is near the mouth of the water filler.

10.When the water level is near the mouth of the water filler, open drain plugs and start the engine, run at low idling and continue to flush the system until clean water comes out. Adjust the flow of the water flowing in and draining out to ensure the radiator is always full during the flushing operation.

11.When clean water comes out, stop the engine, drain all the water, then close drain plugs.

12.Remove the corrosion resistor (if equipped) and open valve.

13.Supply water until it flows over the water filler.

DCA-600SSK — MAINTENANCE

14.Drain the water inside reserve tank, clean the inside of the reserve tank, then fill with coolant/water mixture to between the full and low lines.

15.Stop the engine, wait for 3 minutes, add tap water until the water level reaches near the water filer port, then tighten the radiator cap.

Changing Oil

1.Make sure the oil is cool before changing.

2.Set a container directly under the drain plug of the oil pan. Loosen the drain plug slowly.

3.Check the drained oil for excessive metal particles or foreign material. Contact the distributor if there is metal particles or foreign material.

4.Using a filter wrench, turn filter cartridge to the left to remove it. If the filter cartridge is filled with a large amount of oil, wait 10 minutes or so before removing. Make sure there is no old gasket stuck on the filter holder.

5.Tighten drain plug. Clean the filter holder, fill the new filter cartridge with clean engine oil, coat the packing and thread of the new filter cartridge with engine oil, then install it to the filter holder. Tighten until the gasket surface contacts the seal surface of the filter holder, then tighten it a further 3/4 to 1 turn.

6.Add engine oil through oil filler until the oil level is between the H and L marks on the dipstick.

7.Run the engine at idling for a short time, then stop the engine. Recheck the oil level and fill as necessary.

Replacing Fuel Filter

1.Set the container under the filter cartridge to catch fuel.

2.Using a filter wrench, turn the filter cartridge to the left to remove it.

3.Clean the filter holder, fill the new filter cartridge with fuel, coat the packing surface of the filter cartridge with engine oil, then install the cartridge to the filter holder.

4.When installing, tighten until the packing surface contacts the seal surface of the filter holder then tighten a further 2/3 of a turn. If the filter cartridge is tighten too much, the packing will be damaged and will cause fuel leakage. Fuel leakage will occur if the filter cartridge is not tightened enough. Always tighten to the correct angle.

DCA-600SSK — OPERATION AND PARTS MANUAL (STD)— REV. #7 (04/30/10) — PAGE 53

Page 53
Image 53
Multiquip DCA-600SSK operation manual Flushing Out Radiator and Changing Coolant, Changing Oil, Replacing Fuel Filter

DCA-600SSK specifications

The Multiquip DCA-600SSK is a rugged, reliable, and high-performance mobile generator that caters to a wide range of applications, from construction sites to outdoor events. Designed for durability and efficiency, the DCA-600SSK is notable for its robust construction and advanced technologies that ensure reliable power delivery.

At its core, the DCA-600SSK is powered by a reliable, fuel-efficient diesel engine. This engine not only provides consistent power output but also offers extended run times, making it ideal for long-duration use in remote locations. The generator delivers a remarkable 600 kVA of power, allowing it to support heavy machinery or multiple smaller loads simultaneously.

One of the standout features of the DCA-600SSK is its impressive sound attenuation design. The generator is enclosed in a weather-resistant, sound-attenuated housing that significantly reduces noise levels, making it suitable for use in noise-sensitive environments, such as residential areas or events.

Additionally, the DCA-600SSK is equipped with a user-friendly digital control panel that provides comprehensive monitoring capabilities. This panel includes features such as voltage and frequency regulation, along with automatic start/stop functionality, which enhances both ease of use and operational efficiency. The digital display allows operators to monitor critical parameters at a glance, ensuring optimal performance and safety.

The generator is also designed with mobility in mind. It comes with forklift pockets and lifting hooks, making it easy to transport and relocate. This portability ensures quick setup and deployment, which is especially advantageous in dynamic job sites or temporary power needs.

Another important characteristic of the DCA-600SSK is its dual-frequency capability. It can operate at either 50 Hz or 60 Hz, making it versatile for international applications. This adaptability enables users to utilize the generator in various regions without modifying equipment or loads significantly.

Finally, safety features are paramount in the design of the DCA-600SSK. It includes fully automatic safety shutdowns for low oil pressure, high coolant temperature, and overload protection, safeguarding the generator from potential damage and ensuring dependable performance in demanding conditions.

In summary, the Multiquip DCA-600SSK is a powerhouse generator combining high performance, advanced technology, and user-centric design. Its efficiency, portability, and durability make it an excellent choice for professionals seeking reliable power solutions in various settings.