RPC-4840NRemotePowerController;User'sGuide

7.2. Restoring Saved Parameters

This section describes the procedure for using ProComm to send saved parameters to the RPC-4840N.

1.Start your communications program and access the RPC-4840N command mode using the System Level Password.

2.Configure your communications program to upload an ASCII text file.

3.Upload the file with the saved parameters. If necessary, key in the file name and directory path.

4.When the upload is complete, make certain to terminate the communications program's upload mode.

Note:

￿The current On/Off status of each RPC-4840N circuit will not be saved or restored. However, the selected default On/Off setting for each circuit will be saved and restored.

￿When the configuration file is sent to the RPC-4840N via telnet, the unit's IP Address, Subnet Mask, and Gateway Address cannot be altered.

5.Type /SP and press [Enter], the RPC-4840N will display the Status Screen with passwords revealed. Check the Status Screen to make certain that saved parameters have been restored.

7-2

Page 40
Image 40
Western Telematic RPC-4840N manual Restoring Saved Parameters