Diagnostic Code Chart Energy Smart® Module (ESM)
IMPORTANT: Before attempting to adjust the ther- mostat, read the “Water Temperature Regulation” section page 10.
The Electronic Thermostat (ET) is designed so that it may control the water heater without the Energy Smart® Module (ESM) being operated, see page 12.
If the instructions are not clear, contact a qualified person.
ENERGY | STANDARD VACATION | GRID |
SMART |
| ENABLED |
Error Code
Alert Icon
ALERT
°F/°C
(ESM) ERROR CODE | INDICATES |
| CORRECTIVE ACTION* |
E01 with an alert Icon flashing. | 1. | Turn off electrical power at breaker, add water. | |
| completely full of water. | 2. | Turn on electrical power at breaker. |
|
| 3. | See “Water Heater |
|
|
|
|
E02 with an alert Icon flashing. | Water temperature exceeded high limit. | 1. | Turn off electrical power at the breaker. |
|
| 2. | Press the reset button (see Figure 10A). |
|
| 3. | Turn on electrical power at breaker. |
|
| 4. | If error returns call a service technician for assistance. |
|
|
|
|
E03 with an alert Icon flashing. | Upper thermistor sensor failure. | 1. | Turn off electrical power at the breaker. |
| (Note: Upper thermistor sensor is part of | 2. | Replace Electronic Thermostat (ET). |
| the ET) | 3. | Turn on electrical power at breaker. |
|
|
|
|
E04 with an alert Icon flashing. | Upper element circuit failure. | 1. | Turn off electrical power at the breaker. |
| (Note: Lower element is still operable) | 2. | Check element circuits for resistance of |
|
| 3. | Check wires at elements and Electronic Thermostat (ET) for damage. |
|
|
| If this 4 flashes condition continues, replace Electronic Thermostat (ET). |
|
| 4. | Turn on electrical power at breaker. |
|
|
|
|
E05 with an alert Icon flashing. | Lower element circuit failure. | 1. | Turn off electrical power at the breaker. |
| (Note: Upper element is still operable) | 2. | Check element circuits for resistance of |
|
| 3. | Check wires at elements and Electronic Thermostat (ET) for damage. |
|
|
| If this 5 flashes condition continues, replace Electronic Thermostat (ET). |
|
| 4. | Turn on electrical power at breaker. |
|
|
|
|
E06 with an alert Icon flashing. | Electronic Thermostat (ET) failure | 1. | Turn off electrical power at the breaker. Now turn on electrical power to |
| (Internal processor). |
| see if error clears. If error has not cleared, replace Electronic Thermo- |
|
|
| stat (ET). |
|
| 2. | Turn on electrical power at breaker. |
|
|
|
|
E07 with an alert Icon flashing. | Lower thermistor sensor failure. | 1. | Turn off electrical power at the breaker. |
|
| 2. | Check electrical connections at Electronic Thermostat (ET). |
|
| 3. | Replace Lower Thermistor Sensor. |
|
| 4. | Turn on electrical power at breaker. |
|
|
|
|
E08 with an alert Icon flashing. | Energy Smart® Module (ESM) | 1. | Turn off electrical power. |
| failure. | 2. | Check wires at the interface module for damage. |
|
| 3. | If this 8 flashes condition continues, replace module (ESM). |
|
| 4. | See “Overriding The Interface Module (ESM)” by unplugging from the |
|
|
| Electronic Thermostat (ET) on page 12. NOTE: Electronic Thermostat |
|
|
| (ET) will continue to be operate, hot water will still be available. |
|
| 5. | Turn on electrical power at breaker. |
|
|
|
|
E09 with an alert Icon flashing. | Electronic Thermostat (ET) error. | 1. | Turn off electrical power. |
E10 |
| 2. | Check wiring at Electronic Thermostat (ET) for damage. |
| 3. | Turn on electrical power at breaker. | |
E11 |
| 4. | If this code flashes condition continues, replace the Electronic |
E12 |
|
| Thermostat (ET). |
|
|
|
*These instructions are brief and intended as guidance for a qualified person. If you lack the necessary