DIAGNOSTICS & TROUBLESHOOTING

DIAGNOSTICS

1.Turn off the dehumidifier with the power button.

2.Remove the bucket.

3.Unplug the dehumidifier for at least 1 sec- ond.

4.Reconnect power.

5.Within 5 seconds of restoring power, com- plete the following 3-key entry sequence in this order: Desired Humidity, Fan, and Power.

If you press a wrong key during the 3-key sequence, or if more than 5 seconds elap- ses before completing the sequence, you will need to restart the sequence from the beginning.

After pressing the 3 keys in the correct order within 5 seconds, all the LEDs will light at Step 1 (see chart). Use the Desired Humidity key to advance the steps. Using any other key will exit diagnostics.

IMPORTANT: If you do not complete the diagnostics procedure within 15 minutes, the control will exit the diagnostics.

Step

Test

LED Name

LED Condition

1

LEDs

All

All illuminate

 

 

 

Blinking= Bucket

2a

Bucket switch

Bucket

removed (switch open)

ON solid= Bucket

 

 

 

 

 

 

installed (switch closed)

 

 

 

 

2b

Thermistor

Normal

On solid= Pass

Blinking= Fail

 

 

 

2c

Humidistat

Continuous

On solid= Pass

run

Blinking= Fail

 

 

3

HIGH speed fan

HIGH

ON solid,

confirm operation

 

 

 

4

LOW speed fan

LOW

ON solid,

confirm operation

 

 

 

5

Compressor

AUTO

ON solid,

(On for 20 seconds)

confirm operation

 

 

Exit

 

 

 

5-1

Page 31
Image 31