TROUBLESHOOTING GUIDE ..................................................................................................
PROBLEM | CAUSES | SOLUTIONS |
There is no display. | Check AC power wiring. | Correct any errors. |
|
|
|
The display reads “ERR”. | Electrical noise is entering the system. | Check the SmartPort® wiring harness. |
|
| If the wires were extended then they will |
|
| need to be replaced with shielded cable. |
|
| Contact your local distributor for |
|
| information on shielded cable |
|
|
|
The display reads “P ERR”. | There is a ground fault in the wire to the | Check the master valve or pump start |
| pump start or master valve. | wire for continuity. Replace or repair the |
|
| broken wire. Check that all wire |
|
| connections are good and water tight. |
|
|
|
The display reads a station number | There has been a ground fault with the wire | Check the station wire for continuity. |
and ERR, such as “2 ERR”. | leading to that station. | Replace or repair broken wire. Check |
|
| that all wire connections are good |
|
| and water tight. |
|
|
|
The display reads “NO AC”. | There is no AC power present. | Check to see if the transformer is |
|
| properly installed. |
|
|
|
The display reads “SEN OFF”. | The rain sensor is interrupting irrigation | Slide the Rain Sensor switch on front |
| or not installed. | panel to the OFF position to bypass rain |
|
| sensor circuit. |
|
|
|
The Controller does not start | Potential user programming error. | Check to make sure start time is entered |
automatically. |
| correctly (note AM/PM setting as well). |
|
| Check to make sure watering day is active. |
|
|
|
32