Hunter Fan ICC-800PL Advanced Features, Set Pump/Master Valve Operation, Programmable Rain Off

Models: ICC-801PL ICC-800PL

1 40
Download 40 pages 57.05 Kb
Page 32
Image 32
ADVANCED FEATURES ...........................................................................................................

ADVANCED FEATURES ...........................................................................................................

There are four advanced features available to customize the ICC to more complex watering requirements. Two of these features are “hidden” to make accidentally programming them nearly impossible.

1. Set Pump/Master Valve Operation

The default is for all stations to have the master valve/pump start circuit ON. The master valve/pump start can be set ON or OFF by station, regardless of which program the station is assigned. This feature may be utilized on systems where it is desirable for a booster pump not to operate with certain zones.

2. Programmable Rain Off

This feature permits the user to

SYSTEM OFF

stop all programmed waterings for

 

a designated period from 1 to 7

 

days. At the end of the Rain Delay,

 

the controller will resume normal

 

automatic operation.

 

1.

Turn the dial to the SYSTEM

 

 

OFF position.

 

 

2.

Press the

 

 

button and a 1

 

 

 

 

 

To program pump operation:

1.Turn the dial to SET PUMP OPERATION position.

2.Press the 1. Set Pump/Master Valve Operation or 2. Programmable Rain Off buttons to toggle the Master valve/pump start ON or OFF for the specific station.

3.Press the Manual background button to advance to the next station.

4.Repeat steps 2 and 3 for all necessary stations.

SET PUMP

OPERATION

PUMP

will be displayed and the DAYS icon will illuminate. The 1 will be blinking at this point.

3.Press Manual background as many times as needed to set the number of days off desired (up to 7).

4.To validate this setting (and to make sure the controller comes back on after the period is over), turn the dial back to the RUN position at which time, OFF, a number and the DAYS icon all remain on.

5.Leave the dial in the RUN position.

PUMP

NOTE: The days off remaining will decrease at midnight of each day. When it goes to zero, the display will show the normal time of day and normal irrigation will resume at the next scheduled start time.

28

Page 32
Image 32
Hunter Fan ICC-800PL, ICC-801PL owner manual Advanced Features, Set Pump/Master Valve Operation, Programmable Rain Off