This section will give you a brief overview of some of the components on the ICC. Each item will be discussed in further detail later, however this section can be helpful in getting acquainted with the different options available.
A – LCD Display
1.Program Selector – Identifies the program in use A, B, C, or D.
2.Station Number – Identifies currently selected station number.
3.Main Display – Indicates various times, values, and programmed information.
4.Year – Arrow identifies current calendar year.
5.Month – Arrow identifies current calendar month.
6.Day – Arrow identifies current calendar day.
7.Running – Arrow indicates when watering is occurring.
8.Day of the Week – Arrow identifies days of the week to water. You can also select odd or even and an interval watering schedule.
9.Odd/Even Watering – Arrow identifies if odd or even watering is selected.
10.Interval – Arrow identifies if interval watering has been selected.
11.Seasonal Adjust – Displays in increments of 10%, the percent- age of seasonal adjust that has been selected.
12.Start time – Identifies selected start time. (Only appears on LCD main display when SET WATERING START TIMES is selected.)
B – Control Buttons and Switches
13. Button – Increases the selected flashing display.
14. Button – Decreases the selected flashing display.
15. Button – Advances the selected flashing display to the next item. Also to start a manual cycle.
16. Button – Returns the selected flashing display to the previous item.
17. Button – Selects programs A, B, C, and D. Also to start a test program cycle.
18.Rain Sensor Switch – Allows user to bypass weather sensor if one is installed.
19. and Buttons – Used to increase or decrease the seasonal adjust option.
Akey feature of the ICC is its clear,
C – Control Dial
Run – Normal dial position for all controller automatic and manual operation.
Set Current Date/Time – Allows current date and clock time to be set.
Set Watering Start Times – Allows 1 to 8 start times to be enabled in each program.
Set Station Run Times – Allows user to set each station run time.
Set Days to Water – Allows user to select individual days to water or to select an odd, even, or interval watering schedule.
Set Pump Operation – Allows user to turn off pump or master valve for specific stations.
Manual – Single Station – Allows user to activate a one time watering of a single station.
Manual – All Stations – Allows user to activate a one time watering of all stations or a few selected stations in a selected program.
System Off – Allows user to discontinue all programs and stop all watering until the dial is returned to the RUN position.
3