CONNECTING AC POWER (ICC-800) ....................................................................................
It is recommended that a licensed electrician perform the following power installation.
1.Remove the cover from the junction box.
2.Strip 1/2" off of each wire.
3.For all connections, route the wires through the conduit opening inside the junction box
4.For 120 volt connections twist the wires together using wire nuts as shown in Figure 1. For 230 volt connections twist the wires together using wire nuts as shown in Figure 2.
5.Cap any unused wires. Replace faceplate of junction box and screw into place.
Figure 1 – Junction Box without Terminal Strip (120 Volt)
N Blue Wire (Neutral) |
|
|
|
| 120 Black Wire (120 Volt) | ||||||
|
|
|
| 230 Brown Wire | |||||||
|
|
|
|
|
|
|
| ||||
Green Wire |
|
|
|
| (Use only for 230 Volt | ||||||
(Ground) |
|
|
|
| Connections) | ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Green Wire | White Wire | Black Wire |
Figure 2 – Junction Box without Terminal Strip (230 Volt)
N Blue Wire (Neutral)
Green Wire
(Ground)
120 Black Wire (120 Volt)
230 Brown Wire
(230 Volt)
Green Wire | White Wire | Brown Wire |
9