Hunter Fan ICC-800PL, ICC-801PL Connecting A Pump Start Relay, Power Module, Minimum 4.5 m

Models: ICC-801PL ICC-800PL

1 40
Download 40 pages 57.05 Kb
Page 18
Image 18
CONNECTING A PUMP START RELAY ................................................................................

CONNECTING A PUMP START RELAY ................................................................................

NOTE: Complete this section only if you have a pump and pump start relay installed. A pump start relay is an electronic device that uses a signal current from the irrigation controller to activate a pump to provide water to your system.

The controller should be mounted at least 15 feet (4.5 m) away from both the pump start relay and the pump. When a pump is to be operated by the controller, a pump start relay must be used. Hunter offers a full range a pump start relays for most applications.

1.Route a wire pair from the pump relay into the controller housing.

2.Connect a common wire to the terminal slot C (Common) and the remaining wire from the pump relay to the P/MV screw slot.

Relay holding current draw must not exceed .28 amps. Do not connect the controller directly to the pump – damage to controller will result.

Power Module

PSR Series

Pump Start Relay

 

15' Minimum (4.5 m)

Common Wire

Master Valve Wire

15' Minimum (4.5 m)Common Wire To Pump

14

Page 18
Image 18
Hunter Fan ICC-800PL Connecting A Pump Start Relay, Power Module, Minimum 4.5 m, Common Wire Master Valve Wire To Pump