PEDESTAL MOUNTING THE CONTROLLER .......................................................................
Pedestal Mount, Metal or Stainless Steel Cabinet
1.Assemble the mounting template using the instructions provided with the pedestal.
2.Using the enclosed mounting template, locate the bolts two inches deep in the concrete pad, in the locations indicated. The pad can be any size but at least a
3.Level the mounting bolts before the concrete sets.
4.After the concrete sets, remove the door of the pedestal and slide the pedestal down onto the four bolts. Secure the pedestal to the bolts using the enclosed washers and nuts.
5.Remove the door and faceplate of the ICC and attach the metal cabinet of the ICC to the top of the pedestal using the enclosed hardware in the pedestal.
6.Replace the pedestal door first and then replace the faceplate and the cabinet door. The pedestal door cannot be removed or replaced when the cabinet door is closed.
ICC Controller
Metal Cabinet
ICC Pedestal
Finish Grade |
| Concrete |
|
| (Slope to Drain) |
|
|
|
|
|
|
3/4" (19 mm) Conduit for 120/230 VAC | 1 1/4", 1 1/2" or 2" |
| (32, 40 or 50 mm) |
| Conduit For Valve Wires |