![](/images/new-backgrounds/1051916/5191627x1.webp)
2.If the feet on the bottom of the air conditioner do not rest on the wood strip, remove the air conditioner and adjust the
B A
C
A. Air conditioner
B. Feet on bottom of air conditioner
C. ³⁄₄" (1.9 cm) x 2" (5 cm) wood strip
3.If top channel does not rest against the top of the wall opening, remove air conditioner and adjust
IMPORTANT: The tray must slope downward slightly toward the outside to provide proper drainage for the air conditioner.
A
B
C
A. Top of wall opening
B. Top channel
C. Air conditioner
4.If the bottom of the air conditioner does not sit against the bottom of the
and adjust angle of tray until air conditioner sits against the bottom of the tray.
IMPORTANT: The tray must slope downward slightly toward the outside to provide proper drainage for the air conditioner.
A
B
A. Air conditioner sitting on
B.
5.Install screws through the top channel to secure the air conditioner into the wall opening.
Complete Installation
1.Trim and seal around the air conditioner on the inside and the outside.
NOTE: Allow for removal of the air conditioner at a later time for routine annual maintenance.
WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death, fire, or electrical shock.
2.Plug into a grounded 3 prong outlet.
3.Press RESET on the power supply cord plug.
14