SPECIAL NOTE
To protect the oven and display from overheating, the temperature in the handle is monitored. Therefore the oven may carry out a cooling procedure if overheating is at risk. COOL is displayed during this time. The fan, turntable and light operate. This is normal. After this procedure the oven switches off automatically. The cooling procedure can be interrupted without any harm to the oven by opening the door.
DATA FOR TEST AND HEATING PERFORMANCE
In accordance with IEC 60705.
The International Electrotechnical Commission has developed a standard for comparative testing of heating performance of different microwave ovens. We recommend the following for this oven:
Test | Amount | Approx. time | Power level | Container |
12.3.1 | 1000 g | 11 min | 750 W | Pyrex 3.227 |
12.3.2 | 475 g | 5 min | 750 W | Pyrex 3.827 |
12.3.3 | 900 g | 15 min | 750 W | Pyrex 3.838 |
12.3.4 | 1100 g | Forced air 200 ºC + 350 W | Pyrex 3.827 | |
12.3.5 | 700 g | 25 min | Forced air 200 ºC + 90 W | Pyrex 3.827 |
12.3.6 | 1000 g | Forced air 225 ºC + 350 W | Pyrex 3.827 | |
13.3 | 500 g | 2 min 12 sec | Jet defrost |
|
4619 694 50121
Whirlpool Sweden AB
24