GE C2S980 Gas Supply Requirements, Provide Adequate Gas Supply, Safety Instructions, Operating

Models: C2S980

1 64
Download 64 pages 54.85 Kb
Page 43
Image 43
 Gas Supply Requirements

Read these instructions completely and carefully.

Recommended Gas Pipe Outlet LocationsSafety InstructionsProvide Adequate Gas Supply Gas Supply Requirements

Recommended Gas Pipe Outlet Locations

Safety Instructions

NOTE: Make gas connections on the left side of the cutout opening.

Recommended area for through-the-wall connection of pipe stub/shut-off valve.

30

3”

3”

9”

Operating

This area allows flush installation to rear wall.

7-1/2” 2”

Recommended area for through-the-floorconnection of pipe stub/ shut-off valve.

Provide Adequate Gas Supply

Your range is designed to operate at a pressure of 5 of water column on natural gas or, if designed for LP gas (propane or butane), 10 of water column.

Instructions

Instructions

Installation

 

 

Make sure you are supplying your range with the type of gas for which it is designed.

This range is convertible for use on natural or propane gas. If you decide to use this range on LP gas, conversion must be made by a qualified LP installer before attempting to operate the range on that gas.

For proper operation, the pressure of natural gas supplied to the regulator must be between 5and 13of water column.

For LP gas, the pressure supplied must be between 10and 13of water column.

When checking for proper operation of the regulator, the inlet pressure must be at least 1greater than the operating (manifold) pressure as given above.

The pressure regulator located at the inlet of the range manifold must remain in the supply line regardless of whether natural or LP gas is being used.

A flexible metal appliance connector used to connect the range to the gas supply line should have an I.D. of 1/2and be 5 feet in length for ease of installation. In Canada, flexible connectors must be single wall metal connectors no longer than

6 feet in length.