GE C2S980 Electrical Power Supply Requirements, Provide Proper Electrical Supply, Installation

Models: C2S980

1 64
Download 64 pages 54.85 Kb
Page 44
Image 44
 Electrical Power Supply Requirements

Instructions

Installation of the range.

Operating Instructions Safety

Recommended Electrical Outlet LocationsWall MountedProvide Proper Electrical Supply Electrical Power Supply Requirements

Recommended Electrical Outlet Locations

NOTE: Make electrical connections

on the right side of the cutout opening.

30”

3”

4”

8”

Recommended acceptable electrical outlet area. Orient the electrical receptacle so the length is parallel to the floor.

Wall Mounted

Installation

Instructions

Manual background 2-1/4”

7-1/2”

Product is shipped with 4-prong plug. Recommended outlet is a NEMA 14-50R receptacle.

Consumer Support Troubleshooting Tips

Provide Proper Electrical Supply

These ranges must be supplied with 208/240 volt, 60 Hz., and connected to an individual, properly grounded circuit protected by a circuit breaker or time-delay fuse (40 amp). The receptacle must be NEMA 14-50R to accept the 4-prong plug supplied with the range.

If the electrical service provided does not meet the above specifications, it is recommended that a licensed electrician install an approved outlet.

Locate the electric supply as illustrated.

44

Page 44
Image 44
GE C2S980 Electrical Power Supply Requirements, Provide Proper Electrical Supply, Recommended Electrical Outlet Locations