 Connect the Range to the Gas Supply

Read these instructions completely and carefully.

Flexible Connector HookupRigid Pipe Hookup OptionsManual background Connect the Range to the Gas Supply

Shut off the main gas supply valve before disconnecting the old range and leave it off until the new hookup has been completed. Don’t forget to relight the pilot on other gas appliances when you turn the gas back on.

Safety Instructions

Because hard piping restricts movement of the range, the use of a CSA International-certified flexible metal appliance connector is recommended unless local codes require a hard-piped connection.

Never use an old connector when installing a new range. If the hard piping method is used, you must carefully align the pipe; the range cannot be moved after the connection is made.

To prevent gas leaks, put pipe joint compound on, or wrap pipe thread tape with Teflon* around, all male (external) pipe threads.

Install a manual gas line shut-off valve in the gas line in an easily accessed location outside of the range. Make sure everyone operating the range knows where and how to shut off the gas supply to the range.

Install male 1/2flare union adapter to the 1/2NPT internal thread elbow at inlet of regulator. Use a backup wrench on the regulator fitting to avoid damage.

When installing the range from the front, remove the 90° elbow for easier installation.

Install male 1/2or 3/4flare union adapter to the NPT internal thread of the manual shut-off

valve, taking care to backup the shut-off valve to keep it from turning.

Connect flexible metal appliance connector to the adapter on the range. Position range to permit connection at the shut-off valve.

When all connections have been made, make sure all range controls are in the off position and turn on the main gas supply valve.

Use a liquid leak detector at all joints and connections to check for leaks in the system.

Manual backgroundManual background CAUTION : DO NOT USE A FLAME TO CHECK FOR GAS LEAKS.

When using test pressures greater than 1/2 psig to pressure test the gas supply system of the residence, disconnect the range and individual shut-off valve from the gas supply piping. When using test pressures of 1/2 psig or less to test the gas supply system, simply isolate the range from the gas supply system by closing the individual shut-off valve.

*Teflon: Registered trademark of DuPont

Operating Instructions

Instructions

Installation

Flexible Connector Hookup

Rigid Pipe Hookup Options

Gas Flow into Range

45° Elbow

Pressure regulator

Installer: Inform the consumer of the location of the gas shut-off valve.

Adapter

1/2or 3/4Gas pipe

Gas Flow into Range

Flex Manual background connector (6 ft. max.)

Manual backgroundManual backgroundManual backgroundManual background Adapter

Gas Manual background shut-off valve

 

 

90° Elbow

Nipple

 

 

Black

 

 

iron pipe

 

 

 

Pressure

 

 

Union

regulator

 

 

Union

 

 

 

Nipple

 

 

 

 

 

Gas

 

 

 

shut-off

Installer: Inform the consumer of the

 

valve

location of the gas shut-off valve.

 

1/2or 3/4

 

 

 

Gas pipe

Alternate Hookup

 

Adapter

 

90° Elbow

 

90° Elbow

Nipple

 

Nipple

 

Quick connect

 

 

 

 

or union

Gas

 

Nipple

Pressure

 

regulator

shut-off

 

 

 

90°

valve

 

 

Elbow

 

 

1/2or 3/4

 

 

 

Gas pipe

90° Elbow

 

Installer: Inform the consumer of the

Adapter

 

 

 

location of the gas shut-off valve.

Gas Flow into Range 45