Installation of the range.

TOOLS YOU WILL NEED

Operating Instructions Safety

Phillips and flat-blade screwdrivers

Pencil and ruler

Two pipe wrenches (one for backup)

Open-end or adjustable wrench

Nut driver or wrench: 1/4

Drill

ADDITIONAL MATERIALS YOU MAY NEED:

Gas line shut-off valve

Pipe joint sealant or UL-approved pipe thread tape with Teflon* that resists action of natural and LP gases. *Teflon: Registered trademark of DuPont

Flexible metal appliance connector (1/2 I.D.). A 5- foot length is recommended for ease of installation but other lengths are acceptable. Never use an old connector when installing a new range.

Flare union adapter for connection to gas supply line (3/4 or 1/2 NPT x 1/2 I.D.)

Flare union adapter for connection to pressure regulator on range (1/2 NPT x 1/2 I.D.)

Liquid leak detector or soapy water.

Lag bolt or 1/2 O.D. Sleeve anchor (for concrete floors only).

Squeeze Connector matching the size of the bracket opening (on the range back behind the wiring cover) and the house conduit. Obtain only if replacing the power cord with conduit.

Installation

Instructions

LOCATION GUIDELINES

Do not locate the range where it may be subject to strong drafts. Any openings in the floor or wall behind the range should be sealed. Make sure the openings around the base of the range that supply fresh air for combustion and ventilation are not obstructed by carpeting or woodwork.

Troubleshooting Tips

Your range, like many other household items, is heavy and can settle into soft floor coverings such as cushioned vinyl or carpeting. Use care when moving the range on this type of flooring. It is recommended that the following simple and inexpensive instructions be followed to protect your floor.

The range should be installed on a sheet of plywood (or similar material). When the floor covering ends at the front of the range, the area that the range will rest on should be built up with plywood to the same level or higher than the floor covering.

This will allow the range to be moved for cleaning or servicing. Also, make sure your floor covering will withstand 180°F. (See the Installation Safety Instructions section.)

Make sure the wall coverings around your range can withstand the heat generated (up to 200°F) by the range. (See the Installation Safety Instructions section.)

Consumer Support

IMPORTANT!

Remove all tape and packaging. Make sure the burners are properly seated and level. Take the accessory pack out of the oven.

Check to be sure that no range parts have come loose during shipping.

42

Page 42
Image 42
GE C2S980 installation instructions Operating Instructions Safety, Gas line shut-off valve

C2S980 specifications

The GE C2S980,04-09 JR,49-85167-1,183D5580P249 is a sophisticated control system utilized in various industrial applications, specifically designed for enhancing efficiency and reliability. This model exemplifies advanced technologies and systems integration, catering to the needs of modern industries.

One of the main features of the GE C2S980 is its flexibility, allowing it to be integrated seamlessly into different types of systems. This adaptability makes it suitable for manufacturing plants, power generation facilities, and other industrial environments. The device is engineered for mobility and can be quickly deployed or modified according to the operational requirements of the facility.

A notable technology embedded within the GE C2S980 is its robust data acquisition capabilities. It can gather and process large volumes of data in real-time, which is crucial for effective monitoring and control. This feature enables operators to make informed decisions based on accurate and up-to-date information regarding equipment performance and system health.

Additionally, the GE C2S980 is equipped with advanced diagnostic tools. These tools assist in identifying faults and inefficiencies within the system, thereby reducing maintenance costs and minimizing downtime. Its built-in analytics engine helps in predictive maintenance, enabling industries to foresee potential issues before they escalate into serious problems.

The C2S980 also prioritizes user experience, featuring an intuitive interface that simplifies the navigation of complex controls. This user-friendly design reduces the learning curve for operators, enhancing overall productivity.

Another critical characteristic is its compliance with industry standards, ensuring safety and reliability in various applications. The system is designed to operate in challenging conditions and is built to withstand environmental factors, thus guaranteeing longevity and consistent performance.

In terms of connectivity, the GE C2S980 supports various protocols, facilitating interoperability with other devices and systems. This connectivity is essential for industries that rely on integrating multiple technologies into their operations.

Overall, the GE C2S980,04-09 JR,49-85167-1,183D5580P249 stands out due to its combination of advanced technology, user-centric design, and adaptability to diverse industrial environments, making it an invaluable asset for enhancing operational efficiencies.