Installation of the range.

Read these instructions completely and carefully.

IN THE COMMONWEALTH OF MASSACHUSETTS

This product must be installed by a licensed plumber or gas fitter.

When using ball type gas shut-off valves, they shall be the T-handle type.

A flexible gas connector, when used, must not exceed 3 feet.

BEFORE YOU BEGIN

Installation of this range must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA.54, latest edition. In Canada, installation must conform with the current Natural Gas Installation Code, AN/CGA-B149.1 or the current Propane Installation Code, CAN/CGA-B149.2, and with local codes where applicable. This range has been design-certified by CSA International according to ANSI Z21.1, latest edition and Canadian Gas Association according to CAN/CGA-1.1 latest edition.

Safety Instructions Operating Instructions

As with any appliance using gas and generating heat, there are certain safety precautions you should follow. You will find these precautions in the Important Safety Information section in the front of this manual. Read them carefully.

IMPORTANT: OBSERVE ALL GOVERNING CODES AND ORDINANCES.

NOTE: This appliance must be properly grounded.

IMPORTANT: Save these instructions for the local electrical inspector’s use.

NOTE TO INSTALLER: Leave these instructions with the appliance after installation is completed.

NOTE TO CONSUMER: Keep this Owner’s Manual and Installation Instructions for future use.

SERVICER: The electrical diagram is in an envelope attached to the back of the range.

Instructions

Installation

FOR YOUR SAFETY

Do not store or use combustible materials, gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

Troubleshooting

If you smell gas:

Open windows.

Don’t touch electrical switches.

ELECTRICAL REQUIREMENTS

Extinguish any open flame.

Immediately call your gas supplier.

Tips

CAUTION: FOR PERSONAL SAFETY, DO NOT USE AN EXTENSION CORD WITH THIS APPLIANCE. REMOVE HOUSE FUSE OR OPEN CIRCUIT BREAKER BEFORE BEGINNING INSTALLATION.

This appliance must be supplied with the proper voltage and frequency, and connected to an individual, properly grounded circuit, protected by a circuit breaker or time-delay fuse, as noted on the rating plate.

Wiring must conform to National Electric Codes.

If the electric service provided does not meet the above specifications, have a licensed electrician install an approved outlet.

Because range terminals are not accessible after range is in position, flexible service conduit or cord must be used.

39

Consumer Support

Page 39
Image 39
GE C2S980 Installation of the range, Safety Instructions Operating Instructions, Instructions Installation

C2S980 specifications

The GE C2S980,04-09 JR,49-85167-1,183D5580P249 is a sophisticated control system utilized in various industrial applications, specifically designed for enhancing efficiency and reliability. This model exemplifies advanced technologies and systems integration, catering to the needs of modern industries.

One of the main features of the GE C2S980 is its flexibility, allowing it to be integrated seamlessly into different types of systems. This adaptability makes it suitable for manufacturing plants, power generation facilities, and other industrial environments. The device is engineered for mobility and can be quickly deployed or modified according to the operational requirements of the facility.

A notable technology embedded within the GE C2S980 is its robust data acquisition capabilities. It can gather and process large volumes of data in real-time, which is crucial for effective monitoring and control. This feature enables operators to make informed decisions based on accurate and up-to-date information regarding equipment performance and system health.

Additionally, the GE C2S980 is equipped with advanced diagnostic tools. These tools assist in identifying faults and inefficiencies within the system, thereby reducing maintenance costs and minimizing downtime. Its built-in analytics engine helps in predictive maintenance, enabling industries to foresee potential issues before they escalate into serious problems.

The C2S980 also prioritizes user experience, featuring an intuitive interface that simplifies the navigation of complex controls. This user-friendly design reduces the learning curve for operators, enhancing overall productivity.

Another critical characteristic is its compliance with industry standards, ensuring safety and reliability in various applications. The system is designed to operate in challenging conditions and is built to withstand environmental factors, thus guaranteeing longevity and consistent performance.

In terms of connectivity, the GE C2S980 supports various protocols, facilitating interoperability with other devices and systems. This connectivity is essential for industries that rely on integrating multiple technologies into their operations.

Overall, the GE C2S980,04-09 JR,49-85167-1,183D5580P249 stands out due to its combination of advanced technology, user-centric design, and adaptability to diverse industrial environments, making it an invaluable asset for enhancing operational efficiencies.