LocationRequirements

WARNING

Explosion Hazard

Keep flammable materials and vapors, such as gasoline, away from dryer.

Place dryer at least 18 inches (46 cm) above the floor for a garage installation.

Failure to do so can result in death, explosion, or fire.

You will need

A location that allows for proper exhaust installation. See

Installation spacing for recessed area or closet installation

The following spacing dimensions are recommended for this dryer. This dryer has been tested for spacing of 0" (0 cm) clearance on the sides and rear. Recommended spacing should be considered for the following reasons:

Additional spacing should be considered for ease of installation and servicing.

Additional clearances might be required for wall, door and floor moldings.

Additional spacing should be considered on all sides of the dryer to reduce noise transfer.

For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable.

Companion appliance spacing should also be considered.

Additional spacing is required if you exhaust out the rear of the dryer to either the right or left side.

“Venting Requirements.”

A separate 30-amp circuit.

A grounded electrical outlet located within 2 ft (61 cm) of

either side of the dryer. See “Electrical Requirements.”

A sturdy floor to support the total weight (dryer and load) of

200 lbs (90.7 kg). The combined weight of a companion

appliance should also be considered.

A level floor with a maximum slope of 1" (2.5 cm) under entire

dryer.

Do not operate your dryer at temperatures below 45ºF (7ºC). At lower temperatures, the dryer might not shut off at the end of an

 

 

 

 

14" max.*

48 in. 2 *

 

 

 

 

(35.6cm)

18"*

 

 

 

 

 

(310 cm2 )

 

 

 

 

 

 

(45.7 cm)

 

 

 

 

 

 

 

 

 

 

 

 

24 in.2 *

 

 

 

 

 

 

(155 cm2 )

1"

29"

1"

1"*

29¼"

5"

 

(2.5 cm)

(73.7 cm)

(2.5 cm)

(2.5 cm) (74.3 cm) (12.7 cm)

 

A

 

 

B

 

 

3"* (7.6 cm)

3"* (7.6 cm)

C

automatic cycle. Drying times can be extended.

The dryer must not be installed or stored in an area where it will be exposed to water and/or weather.

Check code requirements. Some codes limit, or do not permit, installation of the dryer in garages, closets, mobile homes or sleeping quarters. Contact your local building inspector.

NOTE: No other fuel-burning appliance can be installed in the same closet as a dryer.

Installation Clearances

The location must be large enough to allow the dryer door to open fully.

Dryer Dimensions

43½" (110.5 cm)

 

22¼"

*29¼"

(56.5 cm)

(74.3 cm)

29"

 

 

(73.7 cm)

A. Recessed area

B. Side view - closet or confined area

C. Closet door with vents

*Required spacing

Mobile home - Additional installation requirements

This dryer is suitable for mobile home installations. The installation must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD Part 280) or Standard CAN/CSA-Z240 MH.

Mobile home installations require:

Metal exhaust system hardware, which is available for purchase from your dealer.

Mobile home Installation Kit Part Number 346764. See “Tools and Parts” section for information on ordering.

Special provisions must be made in mobile homes to introduce outside air into the dryer. The opening (such as a nearby window) should be at least twice as large as the dryer exhaust opening.

*Most installations require a minimum 5" (12.7 cm) clearance behind the dryer for the exhaust vent with elbow. See “Venting Requirements.”

5

Page 5
Image 5
Whirlpool W10054080A manual LocationRequirements, You will need, Installation Clearances, Mobile home installations require