STANDARD CONTROLLER FUNCTIONS
If your unit is installed through the wall and does not have a remote keypad you will have the Standard Controller.
Button/Symbol | Normal Functions | |
ON/OFF | • The ON/OFF button allows the customer the convenience of turning the refrigeration | |
|
| system ON or OFF, from the control panel. This feature does not disconnect power from |
|
| the unit. In order for the power to be shut off from the unit, the power cord must be |
|
| unplugged from the wall receptacle. |
|
| • Press the ON/OFF button once for button application. |
Up and Down | • Use these buttons to scroll up or down the CPSM (Customer Preference Selection Mode) | |
Arrows | menu. | |
|
| • Displays the Highest and Lowest temperature sensed by the Bottle Probe. This feature |
|
| allows the customer instant access to the recorded data applicable to the Bottle Probe |
|
| |
|
| Temperatures, it can be easily reset to reflect current temperatures. |
|
| 1. Press the “UP” arrow, or the “Down” arrow once, and the Highest or Lowest Temperature |
|
| (Hi/Lo) sensed by the Bottle Probe, will be displayed. |
|
| 2. To reset the Hi/Lo, press and hold the “Set” button when the Hi/Lo value is displayed on |
|
| the Digital Display, continue to hold the “Set” button until “rst” appears on the digital |
|
| display and then blinks. This will erase the past recorded “Temperature Data History” and |
|
| start recording, from the current time and temperature, forward. Temperatures displayed |
|
| would reflect Bottle Probe Temperatures from that point in time, and beyond. |
|
| 3. The Hi/Lo feature should be reset at initial |
|
| obtained normal operating temperatures, which is generally 55°F. |
Cellar PreChill (CPC) The CPC Feature is activated by pressing the Up button for
1. The (CPC) Feature may be used to
2.The CPC feature can be conveniently adjusted to the customer’s specific needs, by ac- cessing the “Customer Preference Select Mode” (CPSM). See Customer Preference Select Mode Instructions.
Energy Reduction | 1. The ER feature is activated by pressing the ER button one time, and the ER logo will ap- | |
(ER) |
| pear on the digital display. |
| 2. | The purpose of the ER feature is to reduce energy cost, by shifting the Set Point up by 4 |
|
| degrees, which will allow the cooling system to run for shorter periods of time, resulting |
|
| in a reduction in energy cost. |
| 3. | The ER feature allows for Energy Savings at any time - During periods of high ambient |
|
| temperatures, vacations or business travel. |
| 4. | To deactivate the ER feature, press the ER button one time, and the ER logo will turn off. |
| 5. | The ER feature can be conveniently adjusted specific need by accessing the “Customer |
|
| Preference Select Mode” (CPSM). See CPSM Instructions on page 32. |
Page 31