WhisperKool 5000 owner manual Standard Controller Functions, Button/Symbol, Normal Functions

Models: 5000

1 50
Download 50 pages 44.4 Kb
Page 33
Image 33
STANDARD CONTROLLER FUNCTIONS

STANDARD CONTROLLER FUNCTIONS

If your unit is installed through the wall and does not have a remote keypad you will have the Standard Controller.

Button/Symbol

Normal Functions

ON/OFF

The ON/OFF button allows the customer the convenience of turning the refrigeration

 

 

system ON or OFF, from the control panel. This feature does not disconnect power from

 

 

the unit. In order for the power to be shut off from the unit, the power cord must be

 

 

unplugged from the wall receptacle.

 

 

Press the ON/OFF button once for button application.

Up and Down

Use these buttons to scroll up or down the CPSM (Customer Preference Selection Mode)

Arrows

menu.

 

 

Displays the Highest and Lowest temperature sensed by the Bottle Probe. This feature

 

 

allows the customer instant access to the recorded data applicable to the Bottle Probe

 

 

 

 

Temperatures, it can be easily reset to reflect current temperatures.

 

 

1. Press the “UP” arrow, or the “Down” arrow once, and the Highest or Lowest Temperature

 

 

(Hi/Lo) sensed by the Bottle Probe, will be displayed.

 

 

2. To reset the Hi/Lo, press and hold the “Set” button when the Hi/Lo value is displayed on

 

 

the Digital Display, continue to hold the “Set” button until “rst” appears on the digital

 

 

display and then blinks. This will erase the past recorded “Temperature Data History” and

 

 

start recording, from the current time and temperature, forward. Temperatures displayed

 

 

would reflect Bottle Probe Temperatures from that point in time, and beyond.

 

 

3. The Hi/Lo feature should be reset at initial “Start-Up” and after the Cellar or Cabinet has

 

 

obtained normal operating temperatures, which is generally 55°F.

Cellar PreChill (CPC) The CPC Feature is activated by pressing the Up button for 3-5 seconds, and the CPC logo will be displayed on the digital display. The CPC feature can be terminated by pressing the Up button for 3-5 seconds, or the feature will self terminate after 6 hrs.

1. The (CPC) Feature may be used to Pre-Chill the Cellar prior to loading it with Warm Product. The feature will shift the Set Point down to a lower setting of 52°F, for the next 6 hours. After the 6 hour time period, the Set Point will automatically return to the original Set Point.

2.The CPC feature can be conveniently adjusted to the customer’s specific needs, by ac- cessing the “Customer Preference Select Mode” (CPSM). See Customer Preference Select Mode Instructions.

Energy Reduction

1. The ER feature is activated by pressing the ER button one time, and the ER logo will ap-

(ER)

 

pear on the digital display.

 

2.

The purpose of the ER feature is to reduce energy cost, by shifting the Set Point up by 4

 

 

degrees, which will allow the cooling system to run for shorter periods of time, resulting

 

 

in a reduction in energy cost.

 

3.

The ER feature allows for Energy Savings at any time - During periods of high ambient

 

 

temperatures, vacations or business travel.

 

4.

To deactivate the ER feature, press the ER button one time, and the ER logo will turn off.

 

5.

The ER feature can be conveniently adjusted specific need by accessing the “Customer

 

 

Preference Select Mode” (CPSM). See CPSM Instructions on page 32.

Page 31

Page 33
Image 33
WhisperKool 5000 owner manual Standard Controller Functions, Button/Symbol, Normal Functions