Manual background

Set 1. Press the “Set” button once and it will display the Set Point. After approximately 5 sec- onds, the display will return to normal operation and display the Bottle Probe tempera- ture.

2.Press the “Set” button once and it will display the Set Point. Press the up and down ar- rows to change the set point. Press the Set button again and the numbers will blink, confirming the change in Set Point.

3.Press and hold the “Set” button during the display of the Hi/Low “Temperature Data His- tory” (hold button unit “rst” blinks on display), and it will erase the past recorded data file and start recording, from the current time and temperature.

4.Press the “Set” and the “Down Arrow” buttons simultaneously, for 3-5 seconds, and you will access the “Customer Preference Selection Mode” (CPSM). The CPSM allows the cus- tomer to “Fine Tune” the Control Operating System to their applicable choice.

Alarm The Alarm symbol is shown when the system encounters an issue that needs attention, the displayed alarm codes are explained below.

 

 

Alarm Codes

 

 

 

 

Message

Cause

 

Solution

“P1”

Bottle Probe is Unplugged

 

Attach Bottle Probe to Unit

 

 

 

Faulty Bottle Probe Connection

 

1. Check Bottle Probe attachment at circular connector

 

 

 

 

 

2. Check Bottle Probe connection at green terminal block on

 

 

 

back of controller

 

Defective Bottle Probe

 

Replace the Bottle Probe

“P2”

Faulty Evaporator Probe

 

Check Evaporator Probe connection at green terminal block on

 

Connection

 

back of controller

 

Defective Evaporator Probe

 

Replace the Evaporator Probe

“HA”

Defective Bottle Probe

 

Replace the Bottle Probe

“LA”

The Bottle Probe is sensing a

 

Allow the room to warm up which will increase the temperature

 

temperature of 4° below the set

 

of the wine

 

point

 

 

 

Defective Bottle Probe

 

Replace the Bottle Probe

“POF”

The keypad is locked

 

Hold “Up” and “Down” buttons for 3 to 5 seconds to disable,

 

 

 

“PON” should appear

Page 36