MULTI FAN SPEED CONTROL
Designed for wine cellars up to 1000 and 2000 cubic feet, the Extreme 5000ti/tiR and 8000ti/tiR feature multi- speed fans with a “high” setting for maximum performance in
Fan Speed Selector Switch (Low/Med/High): The cooling unit fans operate on 3 speed settings: Low, Medium, and High. For optimum sound and energy efficiency, select the lowest fan speed that will maintain the desired cellar temperature. If the relative humidity is low, a higher fan speed will cause less moisture to be removed during cooling. High speed is recommended for initial cellar cool down, extreme temperature conditions and ducted installations.
Your fan speed selection will depend on the amount of heat that needs to be removed from the cellar and the ap- plication of the unit (through a wall or fully ducted). Fan speed selection will depend on the cellar size, insulation factor, door seal and desired wine temperature. When initially installing the unit, set the fan speed to High setting for a quick chill down. Once the temperature of the cellar reaches the desired temperature, you may be able to select a lower fan speed to handle the normal load. In the event the temperature outside goes above 90 degrees, (when exhausting to the outside) you may need to select the higher fan speed.
Fully ducted systems need to be set and stay in the High fan speed position.
Model |
| 5000ti & 5000tiR |
|
| 8000ti & 8000tiR |
| |
Speed Selection | Low | Med | High | Low | Med | High | |
Air Flow | 147 | 180 | 256 | 274 | 318 | 333 | |
(CFM) | |||||||
|
|
|
|
|
| ||
Sound | 51/51 | 58/57 | 66/65 | 57/57 | 59/59 | 60/61 | |
(dBA In Cellar / Out of Cellar) | |||||||
|
|
|
|
|
| ||
Cooling Capacity | 2967 | 3142 | 3360 | 5140 | 5606 | 5760 | |
(BTU/h) | |||||||
|
|
|
|
|
|
*To get a feeling for decibels, a food blender at 3ft is 90 dBA, garbage disposal at 3ft is 85 dBA, vacuum cleaner at 10ft is 75 dBA, normal speech at 3ft is 79 dBA, dishwasher in the next room is 55dBA, Quiet night is 35dBA
Page 29