TROUBLESHOOTING GUIDE
Unit leaks water |
|
Possible Cause | Solution |
Unit is not level | Unit should be level in wall to prevent leaking |
|
|
Drain line clogged or kinked | Check drain line to make sure water can flow freely. |
|
|
Drain is clogged preventing water form escaping | Disconnect drain and clear out, open access door and |
| check drain for blockage |
|
|
Drain line does not have a downward slope | Fix Drain line so there is a downward slope from the unit to the drain. |
|
|
Coil is iced causing drain pan ice and water overflowing | Melt ice with blow drier. Soak up with a towel |
|
|
Unit runs but does not cool |
|
Possible Cause | Solution |
Lack of air flow | Make sure fan is unobstructed; clean evaporator if necessary |
|
|
Compressor not running | Call Customer Service at |
|
|
Unit undersized | Call Customer Service at |
|
|
Compressor is overheating | Shut unit off for 1 hour to allow compressor to cool. Turn |
| back on and check for cooler air flow out. If compressor |
| runs, check for and clean condenser coil as possible cause |
| of compressor overheating. If problem repeats, call cus- |
| tomer service. |
|
|
Evaporator fan runs but compressor does not |
|
|
|
Possible Cause | Solution |
Running an | Check evaporator coil temp. |
Compressor and/or starting components faulty | Call Customer Service at |
|
|
Unit may be performing the WHM function | Allow cooling unit to revert back to cooling mode. |
|
|
Compressor may have overheated. | Shut unit off for 1 hour to allow compressor to cool. Turn |
| back on and check for cooler air flow out. If compressor |
| runs, check for and clean condenser coil as possible cause |
| of compressor overheating. If problem repeats, call cus- |
| tomer service. |
|
|
Compressor runs but evaporator fan does not |
|
Possible Cause | Solution |
Faulty fan motor | Call Customer Service at |
|
|
Faulty Controller | Call Customer Service at |
|
|
Compressor short cycles |
|
Possible Cause | Solution |
Evaporator blows on bottle probe | Move bottle probe to a more central location. |
Unit low on refrigerant charge | Call Customer Service at |
Condensing fan motor/capacitor faulty | Call Customer Service at |
Compressor and /or starting components faulty | Call Customer Service at |
|
|
Humidity in cellar too low |
|
Possible Cause | Solution |
Not enough moisture | Raise the Fon setting to increase the humidity level |
|
|
Page 41