To adjust heat anticipation, press CLOCKSET and

To adjust heat anticipation, press CLOCKSET and

ADVDAY at the same time. The display will show

HEAT 18 (this is the factory preprogrammed heating anticipation setting). You may se- lect any anticipation setting from 4 to 40 (note that for add-on heat pump sys- tems, a minimum anticipation setting of

10is recommended). Whenever adjusting anticipation, increase or decrease the dis- played number by only one or two digits, then let the system run for a while to see if the adjustment is sufficient. If the heat cycles

are too short, press TIMEFWD to increase the

cycle time. If the heat cycles are too long,

press BACKTIME to decrease the cycle time. To

SET

set cooling anticipation, press CLOCK and

ADVDAY at the same time again. The display will show COOL 14 (factory preprogrammed

cooling anticipation). Use the TIMEFWD and BACKTIME

buttons to adjust anticipation. To set auxil-

iary heat anticipation, press CLOCKSET and ADVDAY

at the same time again. The display will show AUX 8 (factory preprogrammed cool-

ing anticipation). Use the TIMEFWD and BACKTIME

buttons to adjust anticipation. Press PRGMRUN to return to your program.

LOW BATTERY INDICATOR — The word BATTERY will flash on the display if the 9 volt alkaline battery is low and should be replaced.