TW2000 WOOD-FIRED BOILER – INSTRUCTION MANUAL

SECTION 1 – OPERATING INSTRUCTIONS

KERR TW2000 Wood-Fired Boiler

Tested by: Warnock Hersey Professional Services Ltd. to CSA standard B366.1

Certified by the Canadian Standards Association (CSA) May 1984 COSP. WWP-009

Manufactured by: Parrsboro Metal Fabricators Ltd. P.O. Box 637, Crossroads 12118 Highway 209 Parrsboro Nova Scotia, Canada B0M 1S0

Specifications

Cabinet

Length

36”

 

Width

22”

 

Height

36”

Shipping Weight

 

600 lb.

Fire Box

Length

36”

 

Width

16”

 

Height

26”

Water Volume

US Gallons

26.10

 

IMP. Gallons

21.73

 

Liters

98.80

Heat Exchanger

 

3/16” & 12-gauge steel

Fire Box Door

Cast Iron

13” x 13”

Supply

 

1 ¼”

Return

 

1 ¼”

Smoke Pipe

 

7” Inside Diameter

Smoke pipe exit

 

Top

Output (max):

 

70,000 Btu/h

Fuel:

 

Wood 30” logs maximum

Boiler Water Volume

26.0 U.S. gal.

Domestic Hot Water Coil

Optional

Electrical Rating:

 

Volts 120, 15Amps

NOTE – Keep this manual in a safe place for future reference. Follow manual carefully for the correct way to install and operate this unit.