Windsor CLP12IB, CLP12IE manual 4-2ENG, Solution Pump Replacement, Following Repairs, Maintenance

Models: CLP12IS CLP12IB CLP12IE CLP12IA

1 23
Download 23 pages 5.52 Kb
Page 20
Image 20
SOLUTION PUMP REPLACEMENT

MAINTENANCE

SOLUTION PUMP REPLACEMENT

1.Turn off all switches and unplug the machine.

2.Remove recovery tank.

3.Remove the (2) screws that fasten the solution tank to the frame, and tilt tank back to expose the inside of the frame.

4.Remove solution hoses from fittings in pump.

5.Remove the (2) screws that fasten the pump to the frame.

6.Reverse process to install pump.

Pump Replacement Parts for Shurflo 100 psi (86026400 – PRV NO. 65254)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pump Head

 

Pressure Switch

 

Valve Asm

 

 

 

Diaphram

86251040

 

86161980

 

86258830 - PRV NO. 84161

86235100 - PRV NO. 29206

PRV NO. 65187

PRV NO. 42-809332

 

 

 

 

 

 

 

 

Pump Head

Pump Replacement Parts for Flojet 100 psi 230v (86004770 – PRV NO. 47477) Motor

86247370 - PRV NO. 53246

86251090 – PRV NO. 65204

Valve Asm

Diaphragm

86258860 - PRV NO. 84166

86235120 - PRV NO. 29219

ONLY QUALIFIED MAINTENANCE PERSONNEL ARE TO PERFORM THE

FOLLOWING REPAIRS.

BELT REPLACEMENT

1.Turn off all switches and unplug machine.

2.Remove recovery tank and brush.

3.Remove the (2) screws that fasten the solution tank to the frame, and tilt tank back to expose the inside of the frame.

4.Loosen the (4) screws that hold the brush motor in place and slide motor forward to release tension in belt.

5.Remove the (2) screws that fasten the vacuum shoe links (86227350 - PRV NO. 05016) to the brush housing.

6.Remove the (3) screws that fasten the side plate (86249420 – PRV NO. 62759) to the brush housing to remove belt. NOTE: All components associated with driving the brush will come out with the side plate.

7.Reverse process to install belt.

86249420

PRV NO. 62759

86227350

PRV NO. 05016

4-2ENG

86038280 04/04/07

Page 20
Image 20
Windsor CLP12IB, CLP12IE, CLP12IA manual 4-2ENG, Solution Pump Replacement, Following Repairs, Maintenance, Belt Replacement

FAQ

How do I replace the solution pump on my Windsor Carpet Cleaner?

To replace the solution pump, first turn off all switches and unplug the machine. Remove the recovery tank, then the solution tank. Remove the solution hoses from the pump and the screws that fasten the pump to the frame. Reverse the process to install the new pump. Find replacement parts for Shurflo 100 psi 86026400PRV NO.65254.

Can I replace the belt on my Windsor Carpet Cleaner myself?

Qualified maintenance personnel are recommended to perform belt replacement. However, to replace the belt, first turn off all switches and unplug the machine. Remove the recovery tank, brush, and solution tank. Loosen the screws that hold the brush motor in place and slide the motor forward to release tension in the belt. Remove the vacuum shoe links and side plate to remove the belt. Reverse the process to install the new belt. Find replacement parts for the belt, including 86249420PRV NO.62759 and 86227350-PRV NO.05016.

Where can I find the specific replacement parts for the solution pump and belt on my Windsor Carpet Cleaner?

For replacement parts, refer to the tables in the article for the specific part numbers and PRV numbers for the pump head, pressure switch, valve assembly, diaphragm, and motor.