Windsor CLP12IA, CLP12IB, CLP12IE, CLP12IS manual Troubleshooting Chart, 4-4ENG

Models: CLP12IS CLP12IB CLP12IE CLP12IA

1 23
Download 23 pages 5.52 Kb
Page 22
Image 22

TROUBLESHOOTING CHART

PROBLEM

CAUSE

SOLUTION

 

 

 

 

 

No Power, Nothing

1.

Is the cord plugged in?

1.

Plug in cord.

2.

Circuit breaker tripped in building.

2.

Reset breaker

Runs

3.

Faulty switch.

3.

Call for service.

 

4.

Faulty power cord or pigtail.

4.

Call for service.

 

1.

Vacuum circuit breaker tripped.

1.

Reset breaker

Vacuum Motor Will Not

2.

Faulty main vacuum switch.

2.

Call for service.

Run

3.

Loose wiring.

3.

Call for service.

 

4.

Faulty vac motor.

4.

Call for service.

 

1.

Debris lodged in vac shoe.

1.

Remove debris from vac shoe.

Vacuum Motor Runs

2.

Dome gasket defective or missing.

2.

Replace as necessary.

3.

Vacuum hose cracked or hose cuff

But

3.

Replace or repair as necessary.

 

loose.

Suction Is Poor

 

4.

Turn off vac motor. Drain and rinse

4.

Recovery tank full / float ball stuck in

 

 

recovery tank.

 

 

the up position.

 

 

 

 

 

 

1.

Main pump switch off.

1.

Turn on.

Poor Or No Water Flow

2.

Jets clogged or missing.

2.

Clean using a vinegar /water

 

 

 

solution or replace.

(Carpet Is Streaky)

3.

Solution filter clogged.

3.

Drain solution tank and clean

 

 

 

 

solution filter.

 

4.

Faulty solenoid.

4.

Call for service.

 

1.

Brush switch off.

1.

Turn on brush switch.

Brush Does Not Spin

2.

Brush circuit breaker tripped

2.

Reset circuit breaker.

3.

Brush belt broken.

3.

Replace as necessary.

 

 

4.

Faulty brush motor.

4.

Call for service.

4-4ENG

86038280 04/04/07

Page 22
Image 22
Windsor CLP12IA, CLP12IB, CLP12IE, CLP12IS manual Troubleshooting Chart, 4-4ENG

FAQ

Why is the carpet cleaner not turning on?

Check if the cord is plugged in or if the circuit breaker has tripped. If the issue persists, call for service.

How to improve poor suction of the vacuum motor?

Check for debris lodged in the vac shoe, dome gasket defects, or cracked vacuum hoses. Clean or replace components as necessary.

What to do if the brush is not spinning?

Turn on the brush switch, reset the circuit breaker, or replace the brush belt if broken. If the issue persists, call for service.