Wolf DUAL FUEL RANGES L I N E P R E S S U R E T E S T I N G, Maximum connected load

Models: DUAL FUEL RANGES

1 16
Download 16 pages 16.79 Kb
Page 9
Image 9
L I N E P R E S S U R E

L I N E P R E S S U R E

T E S T I N G

Testing above 1/2 psi (3.5 kPa) 14" (35.6 cm) WC (gauge)

The range and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures greater than 1/2 psig (3.5 kPa).

Testing below 1/2 psi (3.5 kPa) 14" (35.6 cm) WC (gauge) or lower

The range must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa).

E L E C T R I C A L

R E Q U I R E M E N T S

Testing above 1/2 psi (3.5 kPa) 14" (35.6 cm) WC (gauge) WARNING

Verify that power is discon- nected from junction box before proceeding.

Maximum connected load:

5,200 W (30-inch and 36-inch units),

10,000 W (48-inch units), 10,200 W

(60-inch units).

Required power supply: 240V / 30A / 60Hz (30-inch and 36-inch units), 240V / 50A / 60Hz (48-inch and 60- inch units).

Minimum supply wire size (30-inch and 36-inch units): L1 and L2 -

12 AWG, neutral - 16 AWG, ground -

12 AWG.

Minimum supply wire size (48-inch and 60-inch units): L1 and L2 -

8 AWG, neutral - 12 AWG, ground -

10 AWG.

The terminal block on the rear of the range allows for 3-wire or 4-wire installations. For a 4-wire installation, the ground strap from the unit to the terminal block must be cut. Two con- centric knockouts are provided to allow for permanent or cordset wiring of the unit. Please refer to state, municipal and local codes for the best means to connect the appliance to the electrical power supply.

For UL installations: Attach the conductors to the residence wiring in accordance with National Electrical Codes and all state, municipal and local codes.

For CSA installations: Attach the conductors to the fuse box provided. Then connect the residence wiring to the fuse box in accordance with all national, provincial, and local codes. Then, depending upon local codes, utilize one of the following tech- niques to connect the appliance to the electrical power supply.

Connecting to a Four-Wire Electrical System

Cut and / or remove the ground strap on the terminal block.

Connect the white appliance wire to the neutral (white) supply wire on the terminal block.

Connect the black appliance wire to the black (L1) power supply wire on the terminal block.

Connect the red appliance wire to the red (L2) power supply wire on the terminal block.

Connect the ground appliance wire to the green /ground house ground- ing wire on the terminal block.

9

Page 9
Image 9
Wolf DUAL FUEL RANGES L I N E P R E S S U R E T E S T I N G, E L E C T R I C A L R E Q U I R E M E N T S