Leak testing of the appliance shall be conducted according to the following instructions:

Use a brush and liquid detergent to test all gas connections for leaks. Bubbles around connections will indicate a leak. If a leak appears, shut off gas valve controls and adjust con- nections. Then check connections again. Clean all the detergent solu- tion from the range.

WARNING

Never test for a gas leak with a match or other flame.

Put the burner heads on each burner base. Place the burner grates over the burner bases and heads.

A N T I - T I P B R A C K E T I N S T A L L A T I O N

WARNING

This range can tip. Injury to persons could result. Install the anti-tip device packed with this range. Follow these installation instructions.

Raise the unit to its desired height using the rear leveling casters and adjusting the front adjustable legs. Try fitting the unit in place to verify the correct height.

Measure from the floor to the top of the range base flange on the back of the unit.

Add 1/8" to this dimension, and mark this height on the wall behind the unit. This will be the location of the bottom edge of the anti-tip bracket. Try to center the mark between the cabinets. For 48-inch and 60-inch ranges, care must be taken to verify that the anti-tip bracket does not interfere with the inner cavity supports.

Locate a stud or other solid mount- ing source, and install the anti-tip bracket at the same level as this line.

Push the unit back, and ensure the rear base flange fits under the anti-tip bracket.

WALL

SIDE PANEL

 

ANTI-TIP

 

BRACKET

 

BASE FLANGE

5 3/4" min

 

TO FLOOR

 

 

FLOOR

Anti-tip Bracket Installation

11