I N S T A L L A T I O N

P R E - I N S T A L L A T I O N

I N S T A L L A T I O N

C O N S I D E R A T I O N S

Each unit is designed to fit between cabinets set at the distance specified by the unit (i.e. a 36-inch unit will fit a 36" opening). The exception is the 60-inch unit which will require a 60- 1/4" opening.

Unit is designed with a terminal block on the rear of the range. The terminal block will also accept an appliance power cord. Have a certi- fied electrical contractor wire your unit from the junction block to the terminal block on the range.

NOTE: Refer to the chart below and the Installation Dimensions illustra- tions on the following page for exact rough opening dimensions.

IMPORTANT NOTE: Cabinet opening dimensions that are shown must be used. Given dimensions provide for required clearances.

NOTE: Maintain an 18" (45.7 cm) minimum clearance from upper cabinet to countertop, within 6" (15.2 cm) minimum side clearance to combustible surface above countertop.

NOTE: Maintain a 30" (76.2 cm) minimum clearance between top of cooking surface and bottom of wood or metal cabinet, which is protected by not less than 1/4" (.6 cm) flame retardant millboard covered with not less than No. 28 MSG sheet steel,

.015" (.04 cm) stainless steel, or

.024" (.06 cm) aluminum or .02" (.05 cm) copper. Maintain a 36" (91.4 cm) minimum clearance between top of cooking surface and bottom of an unprotected wood or metal cabinet.

IMPORTANT NOTE: Locate the junction box within dimensions shown, flush with back wall.

Total rating: 5.2 kW (240V) for

30-inch and 36-inch units, 10.2 kW (240V) for 48-inch and 60-inch units.

Total Amps: 22 amps for 30-inch and 36-inch units, 43 amps for 48-inch and 60-inch units.

I S L A N D O R P E N I N S U L A I N S T A L L A T I O N S

Island Installation: Unit should not be installed within an enclosure having an adjacent rear wall that rises above the cooking surface. Refer to the chart below and the Installation Dimensions illustrations on the follow- ing page.

Peninsula Installation: Unit has a

6-inch minimum clearance to the side wall, left or right side, and 12-inch minimum clearance to the rear wall.

NOTE: Refer to the chart below and the Installation Dimensions illustra- tions on the following page for exact rough opening dimensions.

Installation Dimensions

30" Range

36" Range

48" Range

60" Range

A

Overall width of range (width may vary to +1/8")

29 7/8"

35 7/8"

47 7/8"

60 1/8"

B

Finished rough opening width

30 "

36 "

48 "

60 1/4"

C

Dimension from edge of rough opening

8 1/2"

8 1/2"

24"

31"

D

Location of gas supply

10"

15"

10"

10"

 

 

 

 

 

 

E

Location of electrical

13"

19"

13"

13"

Note: Dimensions correspond to the illustrations on the following page.