I N S T A L L A T I O N

Connecting the Ground Appliance Wire to the Neutral (white) Supply Wire (three-wire system)

Where Local Codes Permit –

Connect the ground and white appliance wires to the neutral (white) supply wire on the terminal block.

Connect the black appliance wire to the black (L1) power supply wire on the terminal block.

Connect the red appliance wire to the red (L2) power supply wire on the terminal block.

G A S S U P P L Y L I N E

C O N N E C T I O N

IMPORTANT NOTE: All connections must be wrench-tightened. Do not make connections to the gas piping too tight. Making the connection too tight may crack the regulator and cause a gas leak. Do not allow the pipes to turn when tightening fittings as the tubing in the burner box may also bend and begin to leak.

Assemble the flexible metal connector from the gas supply pipe to the pressure regulator. You will need to determine the fittings required, depending on the size of your gas supply line, flexible metal connector and shut-off valve. See illustration below.

Use a pipe-joint compound made for use with natural and LP gas. If a flexible metal connector is used, be certain the tubing is not kinked.

Open the shut-off valve in the gas supply line. Wait a few minutes for the gas to move through the line. Refer to the illustration on page 8.

 

PRESSURE

 

SHUT-OFF

REGULATOR

 

 

 

VALVE

 

 

ADAPTER

ADAPTER

FLEXIBLE METAL

ELBOW

NIPPLE

CONNECTOR

(use pipe-joint

(use pipe-joint

compound on ends)

compound on ends)

 

 

Gas Supply Line Connection

10

Page 10
Image 10
Wolf DUAL FUEL RANGES installation instructions S S U P P L Y L I N E N N E C T I O N, Where Local Codes Permit