Gas Supply Requirements

Multi-Function Cooktop Specifications

6

 

 

Gas Supply Requirements

EXPLOSION HAZARD: Use a certified gas supply line and install a gas shut-off valve. Securely tighten all gas connections. Failure to follow these instructions can result in explosion, fire or death.

IMPORTANT NOTE: This installation must conform with local codes and ordinances. In the absence of local codes, installations must conform with American National Standard, National Fuel Gas Code ANSI Z223.1—latest edition or CANI—B149.1 or 2.

The gas multi-function cooktop is equipped for use with natural or LP gas. It is design certified by the Canadian Standards Association (CSA) for natural or LP gases. The product rating plate, located on the underside of the cooktop, has information on the type of gas that should be used. Refer to the illustration below. If this information does not agree with the type of gas available, contact your authorized Wolf dealer or local gas supplier. For local dealer information, visit the find a showroom section of our website, wolfappliance.com.

GAS SUPPLY LINE

IMPORTANT NOTE: The gas multi-function cooktop must be connected to a regulated gas supply.

Agas supply line of 3/4" (19) rigid pipe must be provided to the cooktop. For LP gas, piping or tubing size can be

1/2" (13) minimum. LP gas suppliers usually determine the size and materials used on the system. If local codes permit, a certified, 1/2" (13) or 3/4" (19) ID flexible metal appliance connector is recommended to connect the cooktop to the gas supply line. The gas pressure regulator on the cooktop has 1/2" (13) female threads.

IMPORTANT NOTE: The supply line must be equipped with an approved external gas shut-off valve located near the cooktop in an accessible location. Do not block access to the shut-off valve. Refer to the illustration below.

The Wolf natural gas multi-function cooktop will function up to an altitude of 10,250' (3124 m) without any adjust- ment. LP gas cooktops will function up to 8,600' (2621 m) without adjustment. If the installation exceeds these eleva- tions, contact your authorized Wolf dealer for a high altitude conversion kit.

RATING PLATE

SHUT-OFF VALVE

OPEN POSITION

TO APPLIANCE

GAS SUPPLY

Before connecting the gas supply, make sure all valves are in a closed position. Do not connect the gas supply to an appliance that shows any sign of damage.

Location of rating plate.

Gas shut-off valve.