I N S TA L L WIRING
I M P O RTA N T N OT E
You must follow all National Electrical Code regulations. In addition, be aware of local codes and ordinances when installing your service.
This ventilation hood liner must be properly grounded and should be installed by a qualified electrician in accordance with all applicable national and local electrical codes.
Before servicing or cleaning, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on acciden- tally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
Run a 120 V AC, 15 amp circuit (minimum) power cable from the service panel to the electrical box in the back of the hood liner.
Insert the conduit through the holes in the back of the hood liner to the electrical box.
Remove the electrical box cover from the back of the hood liner. Connect black wire to power supply black wire, white wire to power supply white wire and green wire to green wire or bare wire.
Place all wiring connections inside the electrical box and reinstall the electrical box cover. Make sure that the wires are secure and that no wires are pinched between the cover and box.
Refer to the wiring diagram packaged with the hood liner for more information.
31/2" (89)
17/8" (48)
121/2"
(318)
Pro hood liner wiring location