Wolf Appliance Company L402212, L582212 B L O W E R W I R I N G, Dimensions for BLOWER-90REM

Models: L462212 L402212 L522212 L342212 L582212

1 16
Download 16 pages 4.97 Kb
Page 13
Image 13
B L O W E R W I R I N G

INSTALLATION I N S T R U C T I O N S

IN-LINEA N D REMOTE B L O W E R S

B L O W E R W I R I N G

IMPORTANT NOTE: Refer to the specific installation instructions provided with each blower for additional wiring instructions.

Follow wiring instructions at the blower as outlined in the specific installation instruc- tions provided with each blower. Black (L1) to black, white (neutral) to white, or white to blue, or white to brown (depending on model) and green to grounding screw. Run blower cable (ROMEX) to the hood liner.

Insert 6" (152) of ROMEX cable through the supplied holes on the back plate and into the hood liner. Secure the cable to the elec- trical box with an appropriate connector.

Locate the cord assembly provided with the blower. The cord assembly has two leads, black (L1) and white (neutral). Connect these leads to the leads from the blower, black to black and white to white.

Connect all green and bare wires together to the ground screw in the electrical box.

Plug the cord assembly into the receptacle located near the center of the hood shell. Use the clips on the interior of the hood to keep excess power cord away from moving parts.

Reinstall the electrical box cover and screws. Make sure that all wires are secure and that no wires are pinched between the cover and box.

IMPORTANT NOTE: Before turning the power on to the ventilation hood liner, make sure the blower is off.

When making electrical connections, make sure the electrical power is turned off at the power source or circuit breaker before proceeding.

 

 

203/4"

281/4"

 

(527)

 

 

(718)

10" (254)

 

 

 

 

Diameter

 

151/2"

 

241/2"

(394)

 

 

 

(622)

 

14"

 

 

(356)

 

 

243/4"

43/4"

 

(121)

 

(629)

 

Dimensions for BLOWER-90REM

Dimensions in parentheses are in millimeters unless otherwise specified.

 

18" (457)

 

10"

291/2"

(254)

(749)

 

10" (254)

 

Diameter

 

143/4"

1

(375)

29 /2"

(749)

 

101/8"

 

(257)

 

22"

71/4"

(559)

(184)

Dimensions for BLOWER-120REM

 

21" (533)

 

10"

291/2"

(254)

 

(749)

 

10" (254)

 

Diameter

 

143/4"

291/2"

(375)

(749)

 

103/8"

 

(264)

 

25"

71/4"

(635)

(184)

Dimensions for BLOWER-150REM