ELECTRICAL REQUIREMENTS

110V Operation

The Shop Fox® W1672 Bandsaw is prewired for 110 volt operation. The motor supplied with your new bandsaw is rated at 1 H.P. and will draw approximately 12 amps. When choosing an outlet for this machine, consider using one with a 15 amp circuit breaker or fuse. Keep in mind that a circuit being used by other machines or tools at the same time will add to the total load being applied to the circuit. Add up the load rat- ings of all machines on the circuit. If this num- ber exceeds the rating of the circuit breaker or fuse, use a different circuit.

Extension Cords

When it is necessary to use an extension cord, use the following guidelines:

•Use cords rated for Hard Service •Never exceed a length of 100 feet •Use cords with 14 ga. wire or bigger •Insure cord has a ground wire and pin •Do not use cords in need of repair

This equipment must be grounded. Verify that any existing electrical outlet and cir- cuit you intend to plug into is actually grounded. If it is not, it will be necessary to run a separate 12 A.W.G. copper grounding wire from the outlet to a known ground. Under no circumstances should the ground- ing pin from any three-pronged plug be removed or serious injury may occur.

Figure 1A. Never remove the grounding pin!

Grounding

This machine must be grounded! See Figure 1B. The electrical cord supplied with the W1672 comes with a grounding pin. Do not remove it. If your outlet does not accommodate a ground pin, have it replaced by a qualified electrician or have an appropriate adapter installed. Please note: When using an adapter, the adapter must be grounded.

Figure 1B. Typical 110V 3-prong plug and outlet.