ADJUSTMENTS
Disc Table Alignment
The disc table clearance has been correctly set at the factory, but over the life of your machine adjustments may need to be made.
To adjust the disc table clearance, do these steps:
1.UNPLUG THE SANDER!
2.Make sure the disc table is set to 0˚.
3.Loosen the four table adjustment bolts (Figure 14).
4.Measure the gap between the table edge and the face of the disc at the left and right end locations.
5.Adjust the clearance at each location to be approximately 1⁄8".
6.Tighten the adjustment bolts when the proper clearance has been achieved.
Adjustment
Bolts