Page: 30 Model BXAUDIO4X4
© 2005 Xantech Corporation
a. When the "PROGRAMMING KEYPAD" LED turns RED, release the "PROGRAMMING
KEYPAD" button.
9. Power up the SLAVE unit.
a. The SALVE unit will go though the normal power up sequence.
b. When the Slave power up sequence ends the Master Zone LEDs will begin to blink RED, the
"PROGRAMMING KEYPAD" LED will be RED, and the "STATUS" LED will turn GREEN.
c. The Slave unit will begin to blink the Zone LEDs ORANGE, the "EXPANSION" LED will be
ORANGE and the "STATUS" LED will turn GREEN.
d. The Master and Slave Zone blinking sequence will continue until the Slave unit has been
cloned with the Master data, approximately 3 ½ minutes.
10. When the sequence ends, power down both units.
11. If the systems will be used in EXPANDED mode, reboot both units.
12. If simply copying one unit to another, remove the EXPANSION cable and disable EXPANDED mode on
both units.

SECTION 7.0: INITIALIZING THE SYSTEM (CLEARING ALL MACRO’S)

Note: Initializing the system will delete ALL macros. This includes all Keypad Button macro’s, Power
Management macro’s, Party Mode settings and Expansion (Master/Slave) settings.
The unit will be restored to Factory Defaults.
To Initialize the System:
1. Power the BXAUDIO4X4 ‘OFF’ via the Power Switch on the rear of the Controller.
2. Place the “Mode” switch on the front panel into the “PGM” up position.
3. Press and Hold the DEL button on the front of the BXAUDIO Controller.
4. Power ‘ON’ the BXAUDIO4X4 via the Power Switch on the rear of the controller.
5. Release the DEL button when the PROGRAM KEYPAD LED turns RED.
6. The PROGRAM KEYPAD LED will turn OFF after 15 Seconds signifying the BXAUDIO4X4 initialization
process is complete and the unit is restored to Factory Default.