Image 10
STATUS LEDs

STATUS LEDs

Status LED

Purpose

 

 

INV/CHRG

Power on light. It will be illuminated whenever the

power switch is on (inverter on) or when there is

(Inverter/Charg

 

incoming AC power and the charger comes on.

 

Illuminates when incoming AC power has been

AC Input

applied and the transfer relays have engaged.

There is a 7-12 second delay from the time the AC

 

 

is applied and this LED illuminates.

 

 

Steady

Indicates an over-temperature condition, the unit is

Overload

shut down. It will reset automatically after cooling.

 

 

 

Inverter mode- Shutdown, diagnose problem using

Blinking

DC Amps bar graph. Charger mode- Thermal

Overload

shutdown, after cooling reset by cycling power

 

switch.

 

 

 

This is a High/Low Battery warning condition.

Steady Battery

Inverter mode: Battery > 15.25 or < 10.50 volts

 

Charger mode: Battery > 15.25 or < 10.00 volts

 

 

 

Indicates either a shutdown or equalizing.

 

Battery > 15.50 volts, will auto-reset at 15.25.

Blinking

Inverter mode: Battery < 10.00 volts, will auto reset

at charger float voltage or upon AC input.

Battery

Charger mode: Battery < 8.00 volts for 1 minute,

 

 

remove all DC loads and manually reset by cycling

 

thedisconnectingpower switchand. reapplying shorepower.

 

 

10