OPERATION

OPERATION

Power Switch

The Power Switch is located on thePower Switch front panel. This switch controls ON/OFF

and RESET for the inverter. Expect a 3 second delay when the power switch is turned ON before the unit is activated.

If the unit is connected to external AC power, the battery charger and transfer switch will continue to function, regardless of the position of the switch.

When external AC power is removed

and the power switch is in the ON position, the inverter will automatically be ON. If the switch is in the OFF position and external AC power is removed, the inverter will be

OFF.

Fleet Power 1000 shown.

Inverter overload protection, transfer switching, power sharing and battery charger regulation will all function automati- cally.

If installed with the remote control panel, the power switch on the unit should be left in the OFF position. Refer to Re- mote Control Panel, page 7.

6

90-0115-00

10/97 Fltman.pm65