The battery charger stages are:

BATTERY CHARGING

NOTE: Fleet Power battery chargers are on whenever there is AC power connected to the charger input, regardless of the condi- tion of the On/Off switch. This feature can be disabled by setting the dip switch #4 (back of the remote) to "On" so that the charger will also be controlled by the On/Off switch.

Each time the battery charger is en- gaged, the 3 stages proceed automatically, resulting in an efficient, complete recharge and safe battery maintenance. Use of the remote control provides the ability to peri- odically apply an 8-hour timed equalizing charge.

The battery charger stages are:

Stage 1 - Bulk Charge During the bulk charge stage most of the charge current is delivered to the battery bank. This phase is engaged as soon as the battery charger is activated. Full rated charger current is delivered to the battery bank until the bulk charge voltage limit is reached. This results in a relatively rapid recharge.

Generally, a wet cell battery bank should not be charged up to the gassing point at a rate which exceeds 25% of its capacity. In other words, a 12 volt battery bank of 520 Amp-hours should not be charged at over 130 Amps.