TROUBLESHOOTING
LED | Indication | |
Number | ||
| ||
|
| |
LED 1 | Illuminates if the unit shuts down for any reason. | |
|
| |
LED 2 | ||
|
| |
LED 3 | The unit detected a failure. Call Heart Interface | |
Technical Support. | ||
| ||
|
| |
| Inverter overload caused by too large a load or | |
LED 4 | short circuit. Reset by cycling power switch or | |
| plugging in incoming AC power. | |
|
| |
LED 5 | Battery overload caused by excessively discharged | |
batteries. Refer to page 40. | ||
| ||
|
| |
| Incoming AC backfeed. Potentially damaging to the | |
LED 6 | unit. Disconnect incoming AC power and correct | |
| the situation. | |
|
| |
LED 7 | Triac thermal run away. Turn OFF and allow to cool | |
down. | ||
| ||
|
| |
| High battery voltage shutdown during charge mode. | |
LED 8 | Check all charging sources for proper voltage. | |
| Reset by cycling the power switch. | |
|
| |
LED | Not used for troubleshooting. | |
|
|