TROUBLESHOOTING

TROUBLESHOOTING

LED

Indication

Number

 

 

 

LED 1

Illuminates if the unit shuts down for any reason.

 

 

LED 2

Over-temperature. Allow to cool.

 

 

LED 3

The unit detected a failure. Call Heart Interface

Technical Support.

 

 

 

 

Inverter overload caused by too large a load or

LED 4

short circuit. Reset by cycling power switch or

 

plugging in incoming AC power.

 

 

LED 5

Battery overload caused by excessively discharged

batteries. Refer to page 40.

 

 

 

 

Incoming AC backfeed. Potentially damaging to the

LED 6

unit. Disconnect incoming AC power and correct

 

the situation.

 

 

LED 7

Triac thermal run away. Turn OFF and allow to cool

down.

 

 

 

 

High battery voltage shutdown during charge mode.

LED 8

Check all charging sources for proper voltage.

 

Reset by cycling the power switch.

 

 