| Troubleshooting Reference |
|
|
|
| |
Table 4 | Troubleshooting reference | |||
Problem |
| Possible Cause |
| Solution |
|
| |||
|
|
|
| |
AC appliance | AC appliance rated |
| Use an AC appliance with a power | |
will not |
| more than 250 watts, |
| rating less than 250 watts. |
operate; the |
| the safety overload has |
|
|
audible alarm | tripped. |
|
| |
is not |
|
|
| AC appliance may exceed the |
sounding. |
| AC appliance is rated |
| |
|
| less than 250 watts, |
| XPower Powerpack’s surge |
|
| high starting surge has |
| capability. Use an AC appliance with |
|
| tripped the safety |
| a starting surge within the XPower |
|
| overload. |
| Powerpack surge rating. |
|
|
|
| |
AC appliance | Battery has discharged |
| Turn the AC Outlet On/Off switch | |
will not |
| to 10.0 volts. |
| off and recharge the XPower |
operate; the |
| Inverter has |
| Powerpack. |
audible alarm |
| Turn the AC Outlet On/Off switch | ||
is sounding. |
| overheated due to poor |
| |
|
| ventilation or |
| off and allow the XPower |
|
| excessively warm |
| Powerpack to cool for 15 minutes or |
|
| environmental |
| more. Clear blocked fan opening or |
|
| conditions. |
| remove objects covering the unit, |
|
|
|
| then restart the XPower Powerpack. |
|
|
|
| Move to a cooler environment. |
|
|
|
|
|
Run time is |
| Internal battery is not |
| Recharge using the AC Charger, |
less than |
| fully charged. |
| until Recharge indicator is green. |
expected. |
| AC appliance power |
| Check AC appliance power or |
|
|
| ||
|
| consumption is higher |
| wattage rating (or current draw for |
|
| than expected. |
| 12 volt DC appliances) and compare |
|
|
|
| |
|
|
|
| |
|
|
|
| |
|
|
|
| |
|
|
|
|
|
37