| Troubleshooting Reference |
|
|
|
| |
Table |
|
| ||
Problem |
| Possible Cause |
| Solution |
|
| |||
|
|
|
|
|
Over- |
| Inverter has |
| Turn off the AC outlet ON/OFF |
temperature |
| overheated due to poor |
| switch, and let the XPower |
shutdown |
| ventilation or |
| Powerpack cool down. |
|
| excessively warm |
|
|
|
| environmental |
|
|
|
| conditions. |
|
|
|
|
|
|
|
Alarm sounds |
| Internal battery is |
| Turn the AC outlet ON/OFF switch |
|
| nearly discharged. |
| OFF and recharge the XPower |
|
| (11.0 V). |
| Powerpack. |
|
| If you ignore this |
|
|
|
| warning, the XPower |
|
|
|
| Powerpack |
|
|
|
| automatically switches |
|
|
|
| off when the battery |
|
|
|
| reaches 10.5 V. |
|
|
|
|
|
|
|
Run time is |
| Internal battery is not |
| Recharge using the AC charger, until |
less than |
| fully charged. |
| green Charging Status light is |
expected. |
|
|
| steady. |
|
| AC appliance power |
| Check AC appliance power or |
|
| consumption is higher |
| wattage rating (or current draw for |
|
| than expected. |
| 12 V DC appliances) and compare |
|
|
|
| with Table |
|
|
|
| |
|
|
|
|
|
35 |