Configuration

Master/Slave Configuration

The Master/Slave system can be configured through the Xantrex Solar GUI (Graphical User Interface) software, P/N 1-152577-01, or through the Operator Interface Panel.

Establish remote or local communication with the GT100E, using the Xantrex Solar GUI software.

To set a unit up as the Master Unit:

1.Click Tools > Inverter Data > Operational Configuration

2.Check the Configured Master check box

3.Click Send Configuration

4.Verify that the Present Inverter Data has the unit set as the Configured Master unit.

Important: If the inverter's date (not the workstation's!) is odd then the Inverter is OPERATIONAL MASTER until midnight; if the inverter's date is even, the Inverter is OPERATIONAL SLAVE until midnight.