Connecting the ICA Cable

Installation

Connecting the ICA Cable

The ICA converts the REMOTE port on the Sine Wave Plus Inverter/Charger into a standard RS232 type communications port interface.

See Figure 1-2 for the location of the Remote Port on the Sine Wave Plus Inverter/Charger.

Important: There are two ports located on the inverter – one is used for the stacking cable and the other is for the remote control port. Make sure you connect the ICA to the correct port. If a Remote Inverter Control Module (ICM-Remote) is being used, it will have to be disconnected while the ICA is in use.

To install the ICA:

1.Connect the ICA adapter to the Sine Wave Plus Inverter/ Charger remote port located on the left end of the inverter, near the AC wiring compartment (Figure 1-2).

2.Connect the phone cable to the RJ11 jack on the gray ICA adapter and to the black serial port adapter.

3.Plug the serial port adapter into the computer’s serial port (Figure 1-2).

4.Check that the LED has illuminated to indicate that it can communicate with the inverter.

Important: On some computers, a DB9-to-25-pin adapter may be needed to allow connection.

4

975-0052-01-01 Rev A